UST SYSTEM ORAUINC INFORMATION <br /> proposed 1, Thret Complete secs at plans (include marwfacturer's specification shears for ori) F� <br /> i nt to be installed), <br /> Plans drawn to scale in non-vrasable print. <br /> 3, t/ Plot plan to Show location of tanks and all associated pipirg- <br /> 4. ✓ Striker places or drop tube-m t&d bottom protectors illustrated below all accessible openings. <br /> S. _✓ Tank cross-sectional diagram_ <br /> 6. Detail of conk, associated piping, excavation and cover, <br /> 7. Tank(s) and piping approved by a nationally recognized independent testing organization. (Title Z3, Chapter 16, <br /> Article 3, Section 2631 (b) i 26351 <br /> 8. verification of product compatibility with the tank(s), piping, monitoring <br /> devica(s), epoxy or silicone glues, etc. <br /> ✓ <br /> 9. Manutacturar's written intullaeton instructions for tmnk(s), piping, amicoring devises, etc. <br /> 10- At the installation size, prior to installation, a tightness test Shall be performed on both primary (14) and <br /> secondary (21) oc ncainswnt systems before covering. (section 2635 (a) (3) i (4)) <br /> 11. Tank integrity test required upon coroletion of installation with tank in operating condition- Test results to be <br /> submitted directly to PMS-[RD from the testing company or owner of facility- CMealth i Safety Code, Division 20, <br /> Chapter 6.7, section 25291 (h)I <br /> 12. YANK COtPOSITICN <br /> TANK Y Y / Y i7 Y t Y <br /> CAPACITY I�000 L�OOO __ <br /> MA)WFACTURGR Tp USCG r1PV5CO <br /> COMPOSITION Fi3eR-5 FIBER-STEEL <br /> MODEL <br /> PRODUCT �-So(-l7✓E G/�SOIaNE <br /> CORAOSIOM PROTECTTOW <br /> V-L. LISTED <br /> CWIPATIBILITY WITH 100% <br /> METHANOL <br /> 13- TAMKCs) TO BE INSTALL® <br /> ✓ <br /> A. Stael-clad with fiberglass reinforced plaatic coatings, eites, or equivalent non-metaLlnc exterior <br /> coatings or eeverings. <br /> (1) Tasted at the instal lotion site wire an eLectruc resistance holiday detector. <br /> (2) Vacuum applied to interstitial space. <br /> _ <br /> B. Fiberglass <br /> (1) Installation instructions require an air test end soap bubble test prior to inatellatica. <br /> (2) vacuum applied to interstitial space. <br /> (3) .Hydraatacic anular-(primary tank press rest)- <br /> C- Non-clad steel conk (sectio. 2635 (a) (2) (A)3 <br /> (1) Cathodic protection provided for entire tank, piping and components (nuts, belts, washers, <br /> '— etc-)- <br /> _ (2) field installed cathodic protection system designed and certified as adequate by a <br /> corrosion IIO@C�ml imt. <br /> (3) Impressed wrrenr systems to be inspected no Less than *very 60 days. <br /> 5 <br />