My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1206
>
2300 - Underground Storage Tank Program
>
PR0231175
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:54:06 PM
Creation date
11/8/2018 9:42:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231175
PE
2361
FACILITY_ID
FA0001247
FACILITY_NAME
DP & DK Investments, Inc.
STREET_NUMBER
1206
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1206 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1206\PR0231175\COMPLIANCE INFO 2011 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2011 - 2017
QuestysRecordDate
4/9/2018 3:51:45 PM
QuestysRecordID
3847565
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility March Lane Shell Facility 1206 E. March, Stockton Inspection Apr 23 2014 <br /> Name: Address: Date: p <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (M1) <br /> Other Violations <br /> 999 Other: HSC 25404(e)(41 See attached"Continuation—Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> This is a Monitoring System Certification and Routine inspection; also observed triennial Secondary <br /> Containment Test being conducted on site. The following are Minor Violations - Notice to Comply: 104, <br /> 204, 310, 311, 999 (HSC 25404 (e)(4)) <br /> 104. Financial responsibility documents were due on April 9, 2014 and have not been submitted to the <br /> EHD. Current financial responsibility documents are required to be submitted annually. Immediately <br /> submit a copy of the financial responsibility documents to the EHD. Alternatively, log into CERS, upload <br /> the required information, and submit for review by the EHD. Complete by May 23, 2014. <br /> 204. The designated operator failed to check and note the correct secondary containment test dates on <br /> the April, May, and June 2013 designated operator monthly inspection reports. During the monthly <br /> inspection, the designated operator shall check that all required testing and maintenance for the UST <br /> system have been completed and document the dates they were done. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. <br /> 311. The 87-octane line leak detector failed to detect a leak when tested. All line leak detectors shall be <br /> capable of detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak <br /> detector, retested it, and it passed. <br /> 310. About 1/2 gallon of liquid was observed in the diesel STP sump. If water could enter into the <br /> secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br /> Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous waste <br /> regulations, and manage it accordingly. Liquid was removed for reuse following secondary containment <br /> test. Ensure sumps are maintained free of liquid. <br /> 999. HSC 25404 (e)(4). The California Environmental Reporting System (CERS) information has not <br /> been updated since it was rejected by EHD in April 2013. All business owners are required to submit <br /> current data from their CUPA hazardous materials programs (UST, hazardous waste generator) to the <br /> state electronically pursuant to A132286. Update CERS by May 23, 2014. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> Inspe Received By: Title: <br /> 2 - v 04K9/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.