Laserfiche WebLink
Appendix VI RECEIVE® <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at hfp://Www.syvr t�c1 tv <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California 'RO <br /> PA TA L <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16,Division 3, Title 23, C� 'r T <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: MARCH LANE 76 Bldg.No.: <br /> Site Address: 1206 E. MARCH LANE City: STOCKTON Zip: 95210 <br /> Facility Contact Person: KARAM SINGH Contact Phone No.: 510-926-7834 <br /> Make/Model of Monitoring System: Veeder Root TLS350 Date of Testing/Servicing: 4/23/2014 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced: <br /> Tank ID: 1-REGULAR Tank ID: 3-Diesel <br /> In-Tank Gauging Probe. Model: MAG r In-Tank Gauging Probe. Model: <br /> r7 Annular Space or Vault Sensor. Model: 409 r Annular Space or Vault Sensor. Model: <br /> PO Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: <br /> r Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> I—V Mechanical Line Leak Detector. Model: Vaporless LD-2000 [7 Mechanical Line Leak Detector. Model: Vaporless LD-2000 <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: EXALARM r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pae 2). Other(specify equipment a and model in Section E on Pae 2). <br /> Tank ID: 2-PREMIUM Tank ID: <br /> In-Tank Gauging Probe. Model: MAG r In-Tank Gauging Probe. Model: <br /> 17 Annular Space or Vault Sensor. Model: 409 r Annular Space or Vault Sensor. Model: <br /> r Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: <br /> I— Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Vaporless LD-2000 r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: EXALRM r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pae 2). r Other(specify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 6 <br /> ID: ID: <br /> Dispenser Containment Sensor(s).Model: 208 170 Dispenser Containment Sensor(s).Model: 208 <br /> Shear Valve(s). rV_ Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 3/4 Dispenser 7/8 <br /> ID: ID: <br /> (vr Dispenser Containment Sensor(s).Model: 208 � Dispenser Containment Sensor(s).Model: 208 <br /> r Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5 Dispenser 9/10 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 208 17 Dispenser Containment Sensor(s).Model: 208 <br /> r Shear Valve(s). rV_ Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):P System set- <br /> up P Alarm history report <br /> Technician Name(print): Timothy Elebeck Signature: <br /> Certification No.: B35252 License. No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 4/23/2014 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />