My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1206
>
2300 - Underground Storage Tank Program
>
PR0231175
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:54:06 PM
Creation date
11/8/2018 9:42:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231175
PE
2361
FACILITY_ID
FA0001247
FACILITY_NAME
DP & DK Investments, Inc.
STREET_NUMBER
1206
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1206 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1206\PR0231175\COMPLIANCE INFO 2011 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2011 - 2017
QuestysRecordDate
4/9/2018 3:51:45 PM
QuestysRecordID
3847565
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECInVEDr Check this box if tank auging is used only for inventor <br /> F.In-Tank Gauging/SIR Equipment: 9 <br /> r Check this box if no tank gauging or SIR a ui t is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> q P� , 15 .2014 <br /> Eff v NMENTgL <br /> Complete the following checklist: HEALTH p <br /> f+' Yes r No* Has all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> r Yes �' No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> r Yes r No* Was accuracy of system product level readings tested? <br /> (70 Yes r No* Was accuracy of system water level readings tested? <br /> r Yes No* Were all probes reinstalled properly? <br /> 16- Yes No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G.Line Leak Detectors(LLD): r Check this box if LLDs are not installed. <br /> Complete the following checklist: <br /> r* Yes (' No* For equipment start-up or annual equipment certification was a leak simulated to verify LLD performance?(Check all that <br /> r N/A apply)Simulated leak rate:r 3 g.p.h.; r 0.1 g.p.h; r 0.2 g.p.h. <br /> C Yes C No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> C Yes (' No* Was the testing apparatus properly calibrated? <br /> r- Yes �' No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> C� N/A <br /> r Yes r No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> G N/A <br /> Yes r No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? <br /> 0 N/A <br /> r Yes (— No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? <br /> (: N/A <br /> r Yes (_ No* For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> G N/A <br /> Yes C No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br /> Page 3 of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.