My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1206
>
2300 - Underground Storage Tank Program
>
PR0231175
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:54:06 PM
Creation date
11/8/2018 9:42:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231175
PE
2361
FACILITY_ID
FA0001247
FACILITY_NAME
DP & DK Investments, Inc.
STREET_NUMBER
1206
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1206 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1206\PR0231175\COMPLIANCE INFO 2011 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2011 - 2017
QuestysRecordDate
4/9/2018 3:51:45 PM
QuestysRecordID
3847565
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 • • Page 1 of 1 <br /> 4.TANK ANNULAR TESTING <br /> Test Method Developed By: r Tank Manufacturer Ce Industry Standard r Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure t: Vacuum r Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: au a Equipment Resolution: .20 <br /> Tank#"3 Diesel ' Tank# 2 PREMIUMTank# 1 REGULAR Tank# <br /> 1s Tank Exempt From Testing?' r Yes to No f Yes to No r Yes t+No r Yes C No <br /> Tank Capacity: 10000 10000 10000 <br /> Tank Material: Fiberglass Fiberglass Fiberglass <br /> Tank Manufacturer: unknown unknown unknown <br /> Product Stored: Diesel PREMIUM REGULAR <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min 5 min min <br /> test: <br /> Test Start Time: 10:36:00 10:43:00 11:00:00 <br /> Initial Reading(RI): 10.00000 in.HG 10.00000 in.HG 10.00000 in.HG <br /> Test End Time: 11:36:00 11:43:00 12:00:00 <br /> Final Reading(RF): 10.00000 in.HG 10.00000 in.HG 9.00000 in.HG <br /> Test Duration: 1 hr 1 hr 1 hr <br /> Change in Reading(Rp-RI): 0.00000 in.HG 0.00000 in.HG -1.00000 in.HG <br /> Pass/Fail Threshold or Criteria: +/-2.00000 +/-2.00000 +/-2.00000 +/- <br /> Test Result: Pass Pass Pass' <br /> Was sensor removed for testing? r Yes Co Nor NA r Yes Co Nor NA r Yes C. No C NA r Yes C Nor NA <br /> Was sensor properly replaced and r Yes f No t* NA r Yes r No f+` NA r Yes f Nor NA r Yes r Nor NA <br /> verified functional after testing? <br /> Comments?(include information on repairs made rior to testing,and recommended ollow-u or ailed tests <br /> RECEIV& <br /> MAY 114 <br /> ENEVIRONMENTA <br /> MENT <br /> t Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment,such as <br /> systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment testing. <br />