Laserfiche WebLink
� <br /> 3 <br /> San Joaquin County <br /> o �sr/zv�� �~��� �����U � ��U� � ��� ��* � ��� <br /> oonna*eron. nsHs <br /> 1868 East Hazelton Avenue <br /> PROGRAM COORDINATORS <br /> Stockton, California �����-���� <br /> " nouortmoc|exnn. nEHa <br /> Jeff ne,me000.nE*a.RDI <br /> nauoyro|eu RsHa <br /> Nebm/bn' ��mx ' mmmrm��o/ <br /> 4. ' -»= ~ unuaTu,xuue.nEHe <br /> Phone: (209)468-3420 Rodney Estrada,Rs*a <br /> Fax: <209\ 464'0138 *u,ionnosxsa000er,RsHa <br /> February 14, 2014 <br /> Carl Wayne Henderson <br /> SST INC <br /> P.O. Box 31465 <br /> Stockton, CAS5213 <br /> Re: March Lane Shell, 1206 E YNamoh Lame, Stockton, CA 95210 SR0069024 <br /> The San Joaquin County Environmental Health Department (EHC}) has completed the review of <br /> the application for o permit to conduct a cold start after "unrecoverable data error' on the <br /> underground storage tank /UST\ eyotarn atthe above noted address. The permit has been <br /> approved with the following conditions: <br /> 1. Contact the |000| fire department and the Son Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any in information and scope ofwork must besubmitted to EHOfor approval <br /> prior tocommencing work. All new addenda supersede the previous ones. <br /> 3. Contact Elena Manzo at C209U 953-7699 to arrange the following inspection <br /> appointments /a 48-hour notice is required for inspection appointments). P|aooe be <br /> aware that inspections for emergency work must be scheduled within five days of permit <br /> approval. <br /> o. Sensor functionality: Functionality of the monitoring eyotenn, including functionality <br /> of all sensors and audible/ visual a|mrnne (since they are port of the overfill <br /> protection), must be verified to ensure that monitoring hos been restored to meet the <br /> requirements of Title 23 California Code of Regulations and the Health & Safety <br /> Code. A copy of the alarm hiatory, printed prior to the ''uo|d start" of the Veeder Root <br /> system, shall bemade available otthe time ofEHOinspection. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> fOUOvviOg: <br /> a. One of several permissible vo|id, current contractor's licenses issued by the <br /> Contractors State License Board (may be issued to the installation company), or a <br /> Tank Tester's license issued to the individual by the State Water Board, and <br /> b. A valid, current California UST Service Technician certificate issued by the <br /> International Code Council /|CC>. and <br /> o. A va|id, current certificate of training from the manufacturer(s) of the component(s) <br /> being teoted, repaired, or serviced. <br />