Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton,California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjaov.ora/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Fac1My . Inspection Nov 18, 2013 <br /> Name; March and Bianchi Chevron Address: 1916 E March Lane, Stockton ale: <br /> Facility Tide: Phone: <br /> Contact Jeet Kaur Manager <br /> Inspection X Routine XMonitoring System Certification Installation 1 i Complaint-ID#: I]Other <br /> Type: <br /> (Authority HSC 25289) Jeet Kaur ride: Manager <br /> Conseri Xlnspection Ii Sampling XPtwos Granted by: <br /> P XPressurized CSuctbn ❑Gravity oveMll XMechanicel C Audible/visual <br /> Pan" Veeder-Root TLS-350 sin: Prever tion: <br /> UST 1 2 3 <br /> ------------ --------------__. ----octane _.91-octane_- -_.-DSL____ ________._ --- ----------- <br /> _ ._ _ _._._ <br /> ._._____._ __.____ _ <br /> Designated Jason Haase ID'aiE"p 2-8-15 VoWtions: XM1-Release Detection tililMeleasePrevemion IIM3-Both <br /> operatoperator <br /> On Site Service James Da ICC Exp Manufacturers VR: 12-13-13, VMI: 5-31-14 <br /> Technician: Y Data. 5-18-15 Training: <br /> VIOLATIONS <br /> # C2 M Code Section HSC=California Health and Code'CCR=Cal'dorria Code of R uletiorls <br /> C7 <br /> C1=Class 1 dolation;C2=Gass 2 violation;M=Minor violation <br /> Fib Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(x)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks tem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 j I X ICCR2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(dXi)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(t)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 X CCR 2638 (e)test notification not provided to the EHD at least 46 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 1 HSC 25291(f) Annual line leak detector test not performed IMtI <br /> 111 I I HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (k11) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping Trot tested for tightness after completion of the repair pursuant to (11112) <br /> Tali conditions <br /> lieHSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 11X10'of public well.or <br /> failures not repaired and retested <br /> 117 CCR 2661 Pen-nd to repair UST system not obtained <br /> 118 HSG 25286(a) Operational permit not amended when UST storage andtor monitoring system changed <br /> 119 HSC 25298(b) Permit to tompwadly close UST system not obtained <br /> 120 IHSC25298 C Permit to dose UST system not obtained <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 X CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other me glaring <br /> equipment, round water elevations,or other test results; fi results of inventoryreadings and reconciliations <br /> 202 CCR 2712(i) Monitoring pian.response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)db not escape secondary containment and cleaned up within eight hours (Mi) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours.or a sudden loss of <br /> roducl was not reported to the EHD within 24 hours <br /> mopgr'. R, IW By, Tlrle' <br /> Garrett Backus (209)466-2986 D-9 m 2 <br /> EHD 23-rr2 Rev 09/19/12 Paget UST INSPECTION REPORT <br />