SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT n <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.siaov.ora/ehd 11 <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Name: March and Bianchi Chevron Aad ss 1916 E March Lane, Stockton Dater`' <br /> °" Nov 21, 2012 <br /> Facility <br /> Contact Title:act: Jeet Kaur Manager Phone: (510) 333-7802 <br /> Inspection XRoutine ❑Monitoring System Certification Installation ❑Complaint-ID#: XOther.Spill container test <br /> Type: P <br /> (Authority HSC 25289) Manager <br /> Consentfor. Xlnspection ❑Sampling XPhotos Grantedby: Jeet Kaur Title: 9 <br /> Monett: Veeder-Root TLS-350 System: XPressurized USuction Il Gravity Piping Overfill Prevention: <br /> Panel: System. XMechanical ❑AudibleMsual <br /> uST1 3 ------- --------- ---- --- ---------- <br /> Product 87-octane 91-octane DSL <br /> Designated ICC Exp.3-1-13 violations: ❑Mt-Release Detection ❑M2-Release Prevention ❑M3-Both <br /> Operator. Jason Haase Date: <br /> hila Service, Jason Haase oa e: 7-10-14 Manufacturers <br /> Technician:: VR: 12M 2013, Contractor (A) 920985 <br /> Te <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> C1=Class 1 violation:C2=Class 2 violation;M=Minor violation <br /> . ... . .Fie-Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 X HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 X CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (Mt) <br /> 111 I HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M7) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2650(k) Repair for lank or piping not tested for tightness after completion of the repair pursuant to (111112) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25296(c) Permit to close UST system not obtained <br /> On Site Records 14 <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and deaned up within eight hours (Mt) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Imp,klor Received By Title: <br /> Garrett Backus (209) 468-2986 le o <br /> EHD 23-02 Rev 04/19/12 Page 1 1 UST INSPECTION REPORT <br />