. 0 <br /> D. Results of TestinglServicing <br /> Software Version Installed:VR 1.01 <br /> Complete the followtn checklist: <br /> X Yes _ No- Is the audible alar operational? <br /> X Yes No* Is the visual alarm operational? <br /> X Yes No• Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> X Yes No• Were all sensors installed at lowest point of secondary containment and pmrtioned so that other equipment will not interfere with their <br /> nminew o ration? <br /> ❑ Yes ❑ Me If alarms am relayed to a remote monitoring station,is all communications equipment(e.g.modern)operational? <br /> X WA <br /> X Yes ❑ No• For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> ❑ WA detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate positive shut-down? (Check all that apply) <br /> X Sump/Trench Sensors; X Dispenser Containment Sensors. Did you confine positive shut-down due to leaks and sensor <br /> failure/disconnection? X Yes; _No. <br /> X Yes No* For tank systems that utilize the monitory system as the primary tank overfill warning device (i.e. no mechanical overfill prevention <br /> WA valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating property? If so,at what percent <br /> of tank capacity does the alarm trigger? 95 % <br /> LXYeX No Was any monitoring equipment replaced? It yes, identify specific sensors, probes, or other equipment replaced anal list the <br /> manufacturer name and model for all rte lacemem ns in Section E,below. <br /> X No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)❑ Product; ❑Water. If <br /> s,describe causes in Section E,below. <br /> LmNo' Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports.it applicable <br /> - No• Is all monitoring equipment operational per manufacturer's spectfications? <br /> .In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> 3 OZ DIESEL WATER MIX FOUND IN THE UDC's AT DISP 9-10 AND 11-12 IT WAS REMOVED AND DISPOSED OF AT THE SITE. <br /> L 15 87 STP SUMP SENSER DID NOT WORK SENSER WAS REPLACED AT TIME OF TEST PERMIT WAS APPLUED FOR. <br /> L 2 DISP 1-2 ANNULAR[MODLE VR 304 X PASS <br /> L4 DISP 3-4 ANNULAR[MODLE VR 304 X PASS <br /> L 0 DISP 5-6ANNULAR[MODLE VR 304 X PASS <br /> L 8 DISP 7-8 ANNULAR[MODLE VR 304 X PASS <br /> L 10 DISP 9-10 ANNULAR[MODLE VR 304 X PASS <br /> L 12 DISP 11-12 ANNULAR[MODLE VR 304 X PASS <br /> L 13 VENT DOX[MODLE VR 208 X PASS <br /> L 14 VENT BOX ANNULAR[MODLE VR 304 X PASS <br /> L 16 87 STP SUMP ANNULAR[MODEL VR 304 X FAIL <br /> L 18 87 FILL SUMP ANNULAR[MODLE VR 304 X PASS <br /> L 20 91 STP SUMP ANNULAR[MODLE VR 304 X PASS <br /> L 22 91 FILL SUMP ANNULAR[MODLE VR 304 X PASS <br /> L 24 DIESEL STP SUMP ANNULAR[MODLE VR 304 X PASS <br /> L 26 DIESEL FILL SUMP ANNULAR[MODLE VR 304 X PASS <br /> Monitoring System Certification Page 2 of 4 12107 <br /> 2 2/21/07 <br />