My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1916
>
2300 - Underground Storage Tank Program
>
PR0527728
>
COMPLIANCE INFO 2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 1:27:18 PM
Creation date
11/8/2018 9:43:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0527728
PE
2351
FACILITY_ID
FA0018792
FACILITY_NAME
MARCH AND BIANCHI CHEVRON
STREET_NUMBER
1916
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09603029
CURRENT_STATUS
01
SITE_LOCATION
1916 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1916\PR0527728\COMPLIANCE INFO 2009 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
9/28/2017 8:32:42 PM
QuestysRecordID
3652760
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Far:(209)468-3433 Web:www.sigov.orci/ehd/unibii.htmi <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> �n� March and Bianchi Chevron ' : 1916 E March Lane, Stockton 'ns <br /> D on Nov 4, 2011 <br /> can'ta'yt: Jeet Kaur Idle: Manager Phone:(510) 333-7802 <br /> Inspection XRoutioe XMonftaing System Certification I.I installation i Complaint-ID# ❑Other: <br /> Type: <br /> (Authority HSC 25289) Jeet Kaur Manager <br /> Consemfor. Xlnspection XSamplirg XPhotos Granted by: Title: g <br /> Monitoring <br /> „ Veeder-Root TLS-350 I P'ong XPressM zea o suction a Gavy XMernaniral ]Aw�l�suatSysemPrevention: <br /> usT 1 2 3 <br /> .- <br /> -�Prodret 87-octane - --91-octane-- -- -.DSL- -- - - - - - - - - - _ --- - - - - -.- -- - - - - <br /> nate <br /> Operatorrd <br /> OJason Haase Icace'7. 3-1-13 Violations XMt-Releass Oetection OW-ReleasePrevention (IM3-Both <br /> On Site Service James Da Ite�. 5-12-13 Manufacturers <br /> Technician: Y Training: VR: 12-1-11 <br /> VIOLATIONS <br /> # C1 I C2 M I Code Section HSC=California Health and Safety Cade;CCR=California Code of Rewfations <br /> C1=Class 1 vioWW;C2=Class 2 violation'M=Minor violation <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25414.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tank s tem <br /> 104 HSC 252922 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(dXIXC) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD at lead 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (M1) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line lightness test not performed if positive shutdown or fail safe not present (Mt) <br /> 113 X CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tghtness after completion of the repair pursuant to (11112) <br /> rmit conditions <br /> 116 HSC 25292.5Enhanced leak detection(ELD)testing not perionned on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 1 1 1 1 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119HSC 25298(b) Permit to temporarily Gose UST system not obtained <br /> 120 HSC 25298(c) Peri[to close UST system not obtained <br /> On SRe Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 61/2 years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment,ground water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M7) <br /> 203 X CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inwe R By. Tile'. <br /> Garrett Backus (209) 468-2986 (Z <br /> EHD 23-02 Rev 09/01/11 Pape 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.