My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1916
>
2300 - Underground Storage Tank Program
>
PR0527728
>
COMPLIANCE INFO 2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 1:27:18 PM
Creation date
11/8/2018 9:43:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0527728
PE
2351
FACILITY_ID
FA0018792
FACILITY_NAME
MARCH AND BIANCHI CHEVRON
STREET_NUMBER
1916
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09603029
CURRENT_STATUS
01
SITE_LOCATION
1916 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1916\PR0527728\COMPLIANCE INFO 2009 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
9/28/2017 8:32:42 PM
QuestysRecordID
3652760
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY �..r <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s'aov.org/ehdiunitiii.htmi <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> FacilkyN.M., March and Bianchi Chevron Facility 1916 E March Lane, Stockton Inspection Nov 4, 2011 <br /> Name: Address: Date: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Code;CFR=Code of Federal R ul�ions <br /> Cl=Class 1 violation;C2=Class 2 violation,M=Mirwr violation <br /> Non-Preseuri Piping(continued) <br /> 702CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1986) (Yi) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M7) <br /> Other violations <br /> 999 Other: See attached"Continuation—Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Routine and Monitoring System Certification Underground Storage Tank Inspection <br /> 113. A new designated operator, Jason Haase, was hired on March 24, 2011 and notification was not <br /> provided to the EHD within 30 days of the change. Any changes shall be reported to the EHD with 30 <br /> days. The inspector made a copy of the notification document during the inspection. <br /> 203. Approximately half a pint of diesel fuel was found in each dispenser 9/10 and 11/12 secondary <br /> containments on 11-4-11 (today) and was not recorded. Any release from the primary containment that <br /> does not escape the secondary containment and was cleaned up within eight hours of being detected <br /> shall be recorded with the following information: <br /> 1. Operator's name and phone number <br /> 2. List of types, quantities, and concentrations of hazardous substances released <br /> 3. Description of actions taken to control and clean the release <br /> 4. Method and location of disposal of the released substances <br /> 5. Description of actions taken to repair and prevent future releases <br /> 6. Description of method used to reactivate interstitial monitoring after repair or replacement of <br /> primary containment <br /> Immediately record this release with the information required, and maintain it on site with the facility's <br /> monitoring records. A form was provided by the inspector to the operator. Submit a copy of the <br /> recordable release statement to the EHD by December 4, 2011. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE HILLER AT THE CURRENT HOURLY RATE <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT li CURRENT HOURLY RATE. <br /> Iriepector Re wd By: TM. <br /> // / ✓✓' <br /> EHD Rev 09/01/11 Page 3 UST INSPECTION REPORT <br />