My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1916
>
2300 - Underground Storage Tank Program
>
PR0527728
>
COMPLIANCE INFO 2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 1:27:18 PM
Creation date
11/8/2018 9:43:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0527728
PE
2351
FACILITY_ID
FA0018792
FACILITY_NAME
MARCH AND BIANCHI CHEVRON
STREET_NUMBER
1916
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09603029
CURRENT_STATUS
01
SITE_LOCATION
1916 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1916\PR0527728\COMPLIANCE INFO 2009 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
9/28/2017 8:32:42 PM
QuestysRecordID
3652760
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12/30/2010 14:15 530774499892 MIDVALLEY CONSULTING PAGE 07 <br /> Monitoring System Certitk smon Form:Addendum for VacuumiPressure InterstA f Sensors LG 163-1,Enc.II <br /> T. Results of Vacunm/Presaure Monitoring Equipment Tenting <br /> This page should be used to dootnment testing and servicing of vacuum and pressure interstitial sensors. A copy of <br /> this form must be included with the Monitoring System Certification Form, which must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the <br /> local agency regulating UST systems within 30 days of test date. <br /> manufacturer VEEDER ROOT Model: system Type:❑Pressure;N Vacuum <br /> Sensor ID .:;,�. ..;,._u ,, �, ..+: s � .t,�..4..• n <br /> Component(s)Monitored by this Sensor: 87 PRODUCT LINE <br /> S1 Sensor Functionality Test Result 9 Pass; ❑ Fail ammsildal Communication Test Result:0 Pass; I] Fail <br /> Component(s)Monitored by this sensor, ALL VENTSIVAPOR <br /> S 2 Sensor Functionality Test Result 0 Pass; ❑ Fail interstitial Communication Test Resalt:0 Pass; ❑ Fail <br /> Componeat(s)Monitored by this Sensor 87 TANK ANNULAR <br /> S 3 Sensor Funakmality Test Result:El Pass; ❑ Fait Interstitial Communication Test Result:0 Pass; ❑ FatT <br /> Component(s)Monitored by this Sensor. 91 PRODUCT LINE <br /> S 4 Sensor Functionality Test Result:®Pass; ❑ Fail interstitial Communication Test Result®Pass; ❑ Fail <br /> Componeat(s)Monitored by this sensor. DIESEL/91 TANK ANNULAR <br /> S5 Sensor Functionality Test Result:El Pass; ❑ Fail interstitial Communication Test Result.®Pass; ❑ Fail <br /> Component(s)MomMered by this Sensor. DIESEL PRODUCT LINE <br /> S6 Sensor Functionality Test Result 0 Pass; ❑ Fail interstitial Communication Test Result®Pass; ❑ Fail <br /> Components)Monitored by this Sensor: <br /> Sensor Functionality Test Result:❑Pass; ❑ Fait Interstitial Communication Test Result❑Pass; ❑ Fail <br /> Componeat(s)Monitored by this Sensor <br /> Sensor Functionality Test Result.❑Pass; ❑ Fail Interstitial Communication Test Result❑Pass; ❑ Fail <br /> Compoment(s)Monitored by this Sensor; <br /> Sensor Functionality Test Result:❑Pass; ❑ Fail latwstitial Communication Test Result:❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor. <br /> Sensor Functionality Test Result:❑Pass; ❑ Fail. interstitial Communication Test Result;❑Pass; ❑ Fail <br /> Hoa was interstitial communication verified? <br /> ® Leak Introduced at Far End of Interstitial Space;' LJ Gane ❑ Visual •tion ❑ Other(Describe in Sec.J below <br /> Vacuum was restored to operating levels in all interstitial spaces; ®yes ❑No(tf no, describe in Sec.J,below) <br /> J. Comments: <br /> Page of <br /> ' If the sensor successfully detects a simulated vacuum/pressure leak introduced in the imtentitial space at the furthest point from the <br /> sensor,vacuum/Ptessure has been demonstrated to be connmunicating throughout the interstice. <br />
The URL can be used to link to this page
Your browser does not support the video tag.