COMPLIANCE INFO 2003 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO 2003 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:07 PM
Creation date
11/8/2018 9:43:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2007
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2132\PR0231669\COMPLIANCE INFO\COMPLIANCE INFO 2003 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2007
QuestysRecordDate
6/24/2016 3:46:18 PM
QuestysRecordID
3117371
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />,'P, Tanlmology <br />TEST DATE:05/03/04 <br />8900 SHOAL CREEK, BUILDING 200 WORK ORDER NUMBER2230833 <br />CLIENT:USA PETROLEUM <br />AUSTIN, TEXAS 78757 (512) 451-6334 SITE:USA #110 <br />Tank ID: 89 2 <br />Tank manifolded: No Bottom to top FII in inches: 96.0 <br />Product: PLUS <br />Vent manifolded: No Bottom to grade in inches: <br />Capacity in gallons: 12,032 <br />Vapor recovery manifolded: YES Fill pipe length in inches: <br />Diameter in inches: 96.00 <br />Overfill protection: YES Fill pipe diameter in inches: <br />Length in inches: 389 <br />Overspill protection: YES Stage I vapor recovery: DUAL <br />Material: DN STEEL <br />Installed: ATG Stage 11 vapor recovery: ASSIST <br />CP installed on: <br />COMMENTS <br />Start (in) <br />End (in) <br />Dipped Water Level: <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />Dipped Product Level: <br />Probe Water Level: <br />Make: RED JACKET <br />Ingress Detected: Water Bubble Ullage <br />Model: Fx1V <br />Test time: <br />S/N: 1706 <br />Open time in sec: 5.00 <br />Inclinometer reading: <br />I <br />Holding psi: 13 <br />VacuTect Test Type: <br />NOT <br />Resiliency cc: 126 NOT <br />VacuTect Probe Entry Point: TESTED <br />Test leak rate ml/m: 189.0 TESTED <br />Pressure Set Point: <br />Metering psi: 10 <br />Tank water level in inches: <br />Calib. leak in gph: 3.00 <br />Water table depth in inches: <br />Results: PASS <br />Determined by (method): <br />Result: <br />COMMENTS <br />COMMENTS <br />Material: <br />ENVIROFLEX <br />Diameter (in): <br />2.0 <br />Length (ft): <br />100.0 <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />NOT NOT NOT NOT <br />Start time: <br />TESTED TESTED TESTED TESTED <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />PRESSURE <br />Pump make: <br />RED JACKET <br />COMMENTS <br />Impact Valves Operational: YES <br />Printed 05/11/2004 08:45 <br />