COMPLIANCE INFO 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/8/2018 9:44:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2132\PR0231669\COMPLIANCE INFO\COMPLIANCE INFO 2016.PDF
QuestysFileName
COMPLIANCE INFO 2016
QuestysRecordDate
6/15/2017 6:48:05 PM
QuestysRecordID
3131588
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Application Guide <br /> Supported Pipe Types and Line Lengths* - For DPLLD, PLLD and WPLLD (Continued) <br /> *lengths approved are for 3.0,0.2,&0.1 gph line leak tests using single pipe types.For mixed line types with DPLLD or PLLD,see footnote 1 and 6 respectively. <br /> FLEXIBLE PIPE-NUPRI (Conti.nued) DPLLD6 PLLD' WPLLD2 BULK MODULUS3 VOLUME <br /> (Feet) (Feet) (Feet) (PSI) (Gallonsi!Foot) <br /> TSMAD-DOUBLE WALL <br /> 1.5 INCH 30-1100 30-1100 No 18900 0.092 <br /> 2 INCH 30-1100 30-650 No 12500 0.163 <br /> 3 INCH _ 30-749 30-300 No 28200 0.367 <br /> TSMAXPD-DOUBLE WALL <br /> 1.5 INCH 30-1100 30-1100 No 15500 0.092 <br /> 2INCH 30-1100 30-650 No 9200 0.163 <br /> 3 INCH 30-749 30-300 No 27800 0.367 <br /> FLEXIBLE PIPE- PETROTECHNIK <br /> PETROTECHNIK UPP EXTRA(63 mm) 20-1100 20-650 No 11,500 0.163 <br /> FLEXIBLE PIPE -TOTAL CONTAINMENT <br /> ENVIBOFLEX RETRACTABLE PIPE <br /> PP1500(1.5 INCH) 10-1100 10-1100 10-500 2400 0.092 <br /> PP1501(1.5 INCH) - 10-1100 10-1100 10-500 3500 0.092 <br /> PPI502(1.5 INCH) 10-1100 10-1100 No 7300 0.092 <br /> PP1503(1.5 INCH) 10-1-100 10-1100 No 2500 0.092 <br /> PP2500 AND PP2501(2.5 INCH) No No No — -- <br /> PP2502(2.5 INCH) 10-1078 10-430 No 8700 0.255 <br /> PP2503(2.5 INCH) 10-1078 10-430 No 3100 0.255 <br /> ONINIFLEX COAXIAL PIPE <br /> CP1501(1.5 INCH) 10-1100 10-1100 10-500 13,000 0.092 <br /> CP1503(1.5 INCH) 10-1100 10-1100 No 4500 0.092 <br /> CP2503(2.5 INCH) 10-1100 20-430 No 3900 0.255 <br /> 'Mixed Piping Types with PLLD: Using TLS-350 software Version 23 or later,PLLD is certified for 3 gph-only testing for line volumes up to 212 gallons;and for <br /> 0.2/0.1 gph testing for line volumes up to 110 gallons.To determine the line volume for mixed piping types,multiply the line length(in feet)times the'gal- <br /> Ions/food!value for each pipe type and add the results.For example,site has 150 feet of 2"fiberglass and 50 feet of 3"fiberglass pipe: <br /> Total line volume= [150 x 0.2041 + [50 x 0.461] =30.6+23.1=53.7 gallons <br /> 2The 0.2 and 0.1 gph line leak tests cannot be run on flex piping with WPLLD. <br /> 3Bulk Modulus entry is only applicable to TLS-350 consoles w/software Version 23 or later and all TLS-450 Series consoles.Refer to TLS-350 System Setup <br /> manual(P/N 576013-623)or TLS-450 Setup Manual(P/N 576013-940)for programming instructions. <br /> 'Geoflex piping produced prior to 2001 has a lower bulk modulus than the current product.For this piping(pre-2001)use the values in().For 2001 piping and <br /> later, you must set the correct Bulk Modulus in the"User Defined"menu. <br /> 'Western Fiberglass COFLEX piping produced prior to 2005 has a different bulk modulus than the current product For piping produced prior to 2005,use the <br /> values in(). <br /> 6Lme lengths shown represent DPLLD approved lengths for 0.2/0.1 gph testing.3.0 gph-only testing for DPLLD is certified for line volumes up to 535.6 gal- <br /> lons(not to exceed 1100 feet of line.See footnote 1 for instructions on calculating line volume for mixed piping. <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.