a <br /> Z, : <br /> VEEDER-ROOT TLS-350 NOTES 4 <br /> NEUTRAL BUS ISOLATED FROM NON-HAZARDOUS AREA HAZARDOUS AREA <br /> PUMP CONTROL GROUND & ELECTRICAL PANEL I WARNING: IN INSTALLATION AND USE OF THIS PRODUCT, COMPLY WITH <br /> BONDING SKREW REMOVED THE NATIONAL ELECTRICAL CODE: FEDERAL, STATE AND LOCAL CODES. �'° �• <br /> FROM DISPENSER ISOLATION PER NEC 250-61(b) IN ADDITION, TURN OFF POWER AND TAKE OTHER NECESSARY <br /> RELAYS RIGID CONDUIT FROM EACH TANK <br /> PRECAUTIONS DURING INSTALLATION, SERVICE AND REPAIR TO <br /> SWITCHED HOT BErIR( 120 OR 240 VAC. ) PREVENT PERSONAL INJURY, PROPERTY LOSS AND EQUIPMENT " <br /> ELECTRICALLY ISOLATED GROUND LOW VOLTAGE SIDE SENSOR LOCATED DAMAGE. <br /> PUMP IN (PI) BUS (INSULATED FROM THE JUNCTION BOX WEATHERPROOF J-BOX IN DISPENSER SUMP DISPENSER vsa <br /> PANEL NA A NON-CONDUCTIVE HYDROSTATIC <br /> MOUNTING) `. WARNING: DISCONNECT ALL POWER BEFORE MAKING AN CONNECTIONS f <br /> SUMP TO PREVENT DEATH, SERIOUS INJURY, EXPLOSION OR ELECTRICAL <br /> o — — SENSOR SHOCK. MONITOR MUST NEVER BE OPERATED UNLESS THE FRONT <br /> z METALLIC CONDUIT, DO NOT <br /> o ROUTE THROUGH AC TROUGH =°aecH COVER IS CLOSED OVER THE BARRIER TERMINALS IN THE NOB <br /> o "I TLS-350R MONITOR SENSOR Locnre0 TYPICAL AT INTRINSICALLY SAFE AREA. HILL <br /> �I� DISPENSER � FOOD S <br /> I 0 w RIGID WEATHERPROOF J-BOX IN DISPENSER SUMP <br /> rn CONDUIT I I NOTES: <br /> in a o ® SEE NOTE 7) + � <br /> � m ® ® ® ® A M h® _ — DISPENSER <br /> L) SUMP 1. WIRING TO PROBES, SENSORS, & PLLD MUST BE SHIELDED MULTI—STRAND, 17, Xw <br /> RED JACKET IO RELAY BOX AC NEUTRAf= <br /> U y <br /> ° � 1' SENSOR GAS AND OIL RESISTANT SIZES FROM AWG #18 TO AWG #14. BARRIER GROUND <br /> L — .° <br /> ......e88Kf <br /> • • m E • WIRING MUST BE AWG #12 OR LARGER. 3al, <br /> vvwvl'Ii�. <br /> AC LINE — MAG PROBE LOCATED WEATHERPROOF J-BOX IN FILL SUMP <br /> CND I ( 2. CONNECT WITH #12 AWG (OR LARGER) CONDUCTOR THE BARRIER GROUND <br /> • • • • wHlrE TANK TO THE EARTH GROUND BUS AT THE POWER DISTRIBUTION PANEL. ' <br /> RIGID CONDUIT meat t�T+c.T+r._�Yr�_-r++� LEVEL _ <br /> CGm+cum-sen m m M21 MI I U I u1 I GAUGING ' <br /> aaeaaaeaaeea weBeeeeeeaee 3. Q. DENOTES FIELD WIRING CONNECTION USING WATERPROOF CONNECTORS sfi' 500 WEST CAPITOL AVENUE <br /> • +w,p smart amw[ • • :a.a mwr¢wwn • . �: <br /> } 804MSUPPLIED WITH THE PROBE(S) AND SENSOR(S). WEST SACRAMENTO CA <br /> SENSOR LOCATED <br /> NEUTRAL 15A — IN FILL/TURBINE SUMP HYDROSTATIC 'rt 95605 <br /> I I 120V L BREAKER • • • — WEATHERPROOF J-BOX 4. INTRINSICALLY SAFE WIRING SHALL BE INSTALLED IN ACCORDANCE WITH <br /> 200-250V CONDITIONED },T,_.a,T._T,.,._T,T,., + � LEAK ARTICLE 504-20 OF THE NEC ANS/NFPA 70, 1990. P.O. BOX 15618 SACRAMENTO C, <br /> POWER SUPPLY PROVIDED I I o . . , , . , , . , . 17 • — DETECTION t� '- <br /> THROUGH PUMPL sssseeeees — — a" a," 95$52 <br /> ELECTRICAL DISTRIBUTION • • • awamwoaawu • — — FILL/TURBINE 5. TO MAINTAIN INTRINSIC SAFETY AND PROPER SYSTEM OPERATION, PROBE. xg <br /> — °east SUMP AND SENSOR WIRING MUST BE INSTALLED WITHIN SEALED CONDUIT. �w�u • REVISIONS <br /> • • • — IN TUR LOCATED t _ <br /> .... ...w �,T_ _T T., IN TURBINE/FILL SUMPSTANDARD 6. ELECTRICAL RATING POWER INPUT — 120VAC, 50/60 HZ, 600 WATTS MAX. ' <br /> + + + +-+ WEATHERPROOFJ-BOX LEAK <br /> I I • aaawee eeeeeeeeee `.�"� — DETECTION <br /> UR <br /> y <br /> • • • a ,� • 7. REFER TO "SITE PREPARATION AND INSTALLATION INSTRUCTIONS," MANUAL <br /> TURBINE/FILL NO. 576013-622 FOR ACTUAL LOCATION OF CONDUIT ENTRY INTO TLS-350 <br /> eases — I I b. SUMP MONITOR. T- <br /> e ACK /p <br /> " • ,°,, • • 4-,T.T._,._�Ta • SINGLE FLOAT SENSOR TYPICAL AT <br /> ® ® IN HYDROSTATIC 8. REFER TO LINE LEAK DETECTOR "SITE PREPARATION AND INSTALLATION," <br /> eeeeeeeeeeeeee III. WEATHERPROOF J-BOX RESERVOIR LEAK TANK MANUAL NO. 576013-764. 3`"+-° <br /> TO TO OTHER awn was ww+we wou <br /> SUBMERSIBLE CONTROLLERS +• � % <br /> PUMP = _ — — DETECTION 9. RS-232 MODULE IS LOCATED IN THE COMMUNICATIONS COMPARTMENT AND <br /> — — — HYDROSTATIC MUST BE ORDERED SEPARATELY. 5 ` <br /> RIGID CONDUIT SEE NOTE 10 }eek RESERVOIR k" . <br /> BELOW 10. BONDING LOCKNUTS AND OR BONDING BUSHINGS SHALL BE USED AT ALL <br /> PLLD SENSOR <br /> I WEATHERPROOF J-BOX IN TURBINE SUMP PRESSURE CONDUIT ENTRANCES TO THE TLS-350R ENCLOSURE AND AT ANY JUNCTION <br /> III LINE LEAK BOX/WIRING TROUGHS IN THE NON-HAZARDOUS AREA TO ENSURE POSITIVE " <br /> OPTIONAL AUDIBLE HORN +• — DEFECTION CONDUIT GROUNDING. G H A U <br /> TURB• INE 11. SOFTWARE ENHANCEMENT MODULE REQUIRED (#330160-012) AND MUST `_ <br /> bL-] SUMPS <br /> y B"cm BE ORDERED SEPARATELY. } .. mP �-7, <br /> 12. FOR 2 PUMPS IN SINGLE TANK OPERATION, PUMP SENSE MODULE <br /> I I SPARE CONDUCTOR REQUIRED (#847490-204) AND MUST BE ORDERED SEPARATELY. IF USING <br /> VACUUM SENSOR �r O u <br /> IN TURBINE SUMPvAc PLLD, PUMP SENSE MODULE IS NOT REQUIRED (ELECTRONIC LINE LEAK . - y ? <br /> WEATHERPROOF J-BOX — I I <br /> UUM SENSOR DETECTOR IS DOING THE PUMP SENSE). = �G( <br /> • IN TURBINE 13. NO SPLICING OF PROBE/SENSOR WIRE EXCEPT AT THE DEVICE ITSELF. TANG ENG�N�� <br /> I — — SUMP <br /> +'eva 14. CONTRACTOR MUST COMPLY WITH ALL THE TRAINING REQUIREMENTS OF ,, "LAND PLANNING AND DESIGN SPECIALISTS" <br /> VEEDER-ROOT. ;a ' 18215 72ND AVENUESOUTH <br /> RIGID CONDUIT FROM EACH TANK "`^` - ,<`Rrr yr,r ...�e-i : <br /> (4 <br /> HIGH VOLTAGE 25) _2-5"1"-'6_2'22 <br /> JUNCTION BOX WIRING SHALL BE INTRINSCALLY <br /> SAFE WIRING G BELDEN CABLE 88760 <br /> I I I I L�— — — — — — — — FOR EACH SENSOR/PROBE (TYP.) "x+- �� SHEET TITLE <br /> VEEDER-ROOT <br /> - - - - <br /> TO TURBINE WIRING <br /> — — — — — — — — <br /> - - - - - - - - - -- - - - - - - - <br /> & CONDUIT <br /> w DIAGRAMS <br /> _ <br /> BCE #12004 <br /> Typical Veeder— Root & Turbine Relay Wiring Diagram PROJECT NAME <br /> SCALE: NTS , A L EYE S <br /> #356 <br /> FRONTAGE ROAD & <br /> MORADA LANE <br /> STOCKTON, CALIFORNIA <br /> PROJECT NO. <br /> 2.3208.000 <br /> DRAWN BY <br /> .0 AS <br /> ^,q o SCALE <br /> AS SHOWN <br /> �rh HAL P y V <br /> Y <br /> 7 67 4 m <br /> A b <br /> >w1 DATE <br /> 3016 + 23 JUNE 2005 <br /> CIVid <br /> PAGE NO. <br /> TK7-5Nay dh <br /> �U <br /> NOTE: INDICATES ITEMS FOUND <br /> �X MATERIALS LIST ? � SHEET <br /> OF <br /> ;wF <br />