Laserfiche WebLink
Vacuum Sensor System Installation Guide Vacuum Connections within Sump <br /> Vacuum Connections to Siphon Port of the Pump <br /> 1. Get the 1/4" NPT/barbed adapter from the mounting kit.Apply sealant to the threads of the fitting and screw <br /> it into the STP siphon port (see Figure 13). <br /> Cl <br /> OOO 1/4" NPT to 1/4" barbed adapter <br /> Spring clamp <br /> / ��1/4"ID tubing connects <br /> STP siphon to Vac Sensor vacuum <br /> vacs"naorfligl2.epa p <br /> cartridge manifold <br /> Figure 13. Attaching 1/4"nylon tubing to STP siphon cartridge <br /> 2. Measure a length of 1/4" ID tubing to connect 1/4"ID barbed tubing fitting in the siphon cartridge port and <br /> the vacuum input tee of the Vac Sensor system (see Figure 14).Plan enough tubing to avoid sharp bends in it <br /> or stretching it. Cut and install this tubing and secure tubing ends with spring clamps. <br /> p <br /> xQ / 1/4"ID tubing to <br /> ✓ siphon port in STP <br /> Spring damp <br /> Figure 14. Connecting vacuum tubing from pump siphon port to Vac Sensor system <br /> 14 <br />