PE
2351
FACILITY_ID
FA0016523
FACILITY_NAME
RALEYS FUEL STATION #356
STREET_NUMBER
4219
Direction
E
STREET_NAME
MORADA
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12429017
CURRENT_STATUS
01
SITE_LOCATION
4219 E MORADA LN
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MORADA\4219\PR0524617\INSTALL 2007.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Piping information continued- <br /> Check <br /> Box Code <br /> Section <br /> ® 252s0.1(cx0 Piping compatible with material intended to be stored. <br /> 25290.2(c)(1) <br /> 0 2331CR Design and construction of piping approved by independent testing organization(e.g.UL). <br /> 26 ( <br /> ® Piping,including vent lines,sloped toward tanks with minimum 1/4 inch sloe per 1 foot of run. <br /> HSC <br /> 0 252901C&0> 1 Vapor recovery,fill riser,and vent line piping are secondarily contained. <br /> G. OVERSPILL/OVERFILL PREVENTION: <br /> Check <br /> Bax Code <br /> S.M. <br /> ® 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> 2635(b) Manufacturer PHIL—TITS Model SC-3600—TSC-2—I—EVR <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> ❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> L Restrict delivery of flow to the tank at least 30 minutes before the tank overfills,provided the <br /> restriction occurs when the tank is filled to no more than 95 percent capacity;and activate an audible <br /> ® 23 CCR alarm at least five minutes before the tank overfills <br /> 2635(6x2) <br /> ❑ Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> 4R Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer PHIL—TITE Model SC-3600—TSC-2—I—EVR <br /> H. CORROSION PROTECTION: <br /> Check <br /> go� Code <br /> Section <br /> Y Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: i Steel with cathodic protection or impressed current <br /> ® 23 CCR Steel isolated from contact with backfill <br /> 2636(6) <br /> X FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: I Sacrificial Anode <br /> ® 23 CCR ❑ Steel tank with field installed cathodic protection or impressed <br /> 2635(ax2) <br /> current <br /> ® Tie-downs,when used,constructed of non-corrosive material or coated steel. <br /> - 7 - <br />