Underground Storage Tank Program Inspection Report <br />Date: <br />September 29, 2017 <br />Facility Address: <br />2849 E Myrtle St, Stockton <br />Facility Name: <br />Regional Transportation Center <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone:(209) 468-3420 Fax :(209) 468-3433 Web:www.sjgov.org/ehd <br />UST System Observations <br />322 □ V □ R □ COSUnburied below grade emergency generator system failed to meet exemption statusHSC 25281.6(a) <br />323 □ V □ R □ COSUnburied below grade UST system failed to meet exemption statusHSC 25283.5(a) <br />324 □ V □ R □ COSTampered with red tagCCR 2717.1(g) <br />325 □ V □ R □ COSDeposited petroleum into a red tagged USTCCR 2717.1(f) <br />326 □ V □ R □ COSTampered with or disabled leak detection devices or alarmsHSC 25299(a)(9) <br />327 □ V □ R □ COSUST system not compatible with the substance storedCCR 2631.1 <br />328 □ V □ R □ COSFailed to comply with temporary closure requirementsHSC 25298 <br />329 □ V □ R □ COSFailed to comply with permanent closure requirementsHSC 25298 <br />330 □ V □ R □ COSFailure to meet all requirements in lieu of a line leak detector for emergency generator tank systemCCR 2636(f)(6) <br />Single-Walled Non-Pressurized Piping <br />401 □ V □ R □ COSSuction piping not properly sloped or incorrectly located check valveCCR 2636(a)(3) <br />402 □ V □ R □ COSDaily monitoring of suction pipe (pre-Jan 1984) not performedCCR 2643(d) <br />403 □ V □ R □ COSTriennial 0.1 gph line test for conventional suction piping not performed (pre-January 1984)CCR 2643(d) <br />404 □ V □ R □ COSBiennial 0.1 gph test for gravity piping not performed (pre-January 1984)CCR 2643(e) <br />Other Violations <br />2010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br />2030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br />2060 □ V □ R □ COSUnlisted Design/Construction violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Overall Inspection Comments: <br />REINSPECTION <br />**This inspection report is an addendum to the previous inspection report issued on 9/25/17. It does not replace <br />the previous inspection report. <br />Witnessed the 87 leak detector testing. Passed. The annual testing is complete. <br />Note: All EHD staff time associated with this reinspection will be billed at the current hourly rate. <br />**According to Eric Molgaard of Bagley Enterprises and Wendell Krell, the plug in the shear valve on dispenser <br />NR-1 stuck. The facility employees attempted to drill out the plug. During drilling, the bit became stuck in the plug <br />Page 3 of 4