My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2021 11:01:14 AM
Creation date
11/8/2018 9:46:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MYRTLE\2849\PR0538822\COMPLIANCE INFO 2018 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2018 - PRESENT
QuestysRecordDate
4/13/2018 5:07:30 PM
QuestysRecordID
3854464
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I am currently in touch with Hopkins Manufacturing to assist us in verifying that the funnel we used as a splash guard, <br /> see attached photo, is predominantly a polypropylene product and totally compatible with gasoline and diesel fuel, see <br /> attached chemical compatibility chart, pages 4/13, 5/13, and 13/13. I expect to hear back from the Manufacturer either <br /> later today or sometime tomorrow. <br /> 2. I understand the manufacture of the pump was contacted and they said there is no existing device <br /> made. If we can get an email or something from them saying there is no device available for the <br /> purpose the County is asking they will may accept that as well. <br /> I have been in touch with S. Bravo, the manufacturers of the Deflector Plates for"other than Gasboy Dispensers"(see <br /> attached drawings for Ovation and Encore dispensers and photo showing red dotted line of leakage being deflected into <br /> UDC). S. Bravo is aware of the need for a deflector plate for Gasboy Atlas series dispensers but do not currently have <br /> anything in production. <br /> I will keep you posted, Joe <br /> Joseph Bagley(Capt. USAF-Ret),General Manager <br /> Bagley Enterprises, Inc.,SB-DVBE,SDVOSB <br /> General Engineering&Construction Lic#774802 A, B, HAZ, C61(D21,D34,D40) <br /> DIR# 1000012690 <br /> GSA Contract#'s: GS-07F-0462Y <br /> CMAS Contract#'s 4-13-56-0051A <br /> 2370 Maggio Circle, Ste 4, Lodi, CA 95240 <br /> T#(209) 367-4800/F#367-5424/C#329-0582 <br /> E-mail:joe@bagleyenterprises.com <br /> Website:www.bagleyenterprises.com <br /> **Confidentiality Note:This e-mail is intended only for the person or entity to <br /> which it is addressed,and may contain information that is privileged,confidential, <br /> or otherwise protected from disclosure. Dissemination,distribution,or copying of <br /> this e-mail or the information herein by anyone other than the intended recipient(s) <br /> is prohibited.If you have received this e-mail in error, please notify the sender <br /> by reply e-mail and destroy the original message and all copies. <br /> From: Joseph Bagley [mailto:joe@bagleyenterprises.com] <br /> Sent: Friday, February 23, 2018 1:09 PM <br /> To: 'srivera@sjcehd.com'; 'Elena K. Manzo [EH]'; 'John Alaniz [EH]' <br /> Cc: 'cory.hootman@waterboards.ca.gov'; Terry Masters'; 'Douglas Smith' <br /> Subject: FW: Permit To Operate (PTO) for SJRTD <br /> Hello Stacy, <br /> Re:SJRTD and the withholding of their PTO.....please reference our telephone conversation on Wednesday regarding our <br /> use of attaching a funnel under the Gasboy 9800 dispenser filter to ensure that....if a leak occurred....the leak would be <br /> deflected into the UDC. If I recall correctly you were satisfied that our funnel would indeed deflect a leak into the UDC <br /> but nevertheless you were not prepared to sign off on our remedy because it was not a fix that was approved by the <br /> State Water Board and was not listed in LG113. I did a fair amount of research regarding this issue trying to find a "state <br /> approved" deflector plate for a Gasboy 9800 dispenser. It did not take me too long to determine that there is no such <br /> thing on the market. <br /> Thinking that I may have to actually design something and try to have it approved by the State I found myself in contact <br /> with Cory Hootman at the State Water Board and he was able to give me some very good insight into how we have <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.