My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2022 11:21:35 AM
Creation date
11/8/2018 9:47:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\C\CAMBRIDGE\16470\PR0231532\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
10/22/2012 8:00:00 AM
QuestysRecordID
131132
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
993
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> '`I►Tanknology <br /> TEST DATE: 10/14/10 8501 N EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2277281 <br /> AUSTIN,IN,TEXAS 78759(512)451-6334 <br /> CLIENT: CIRCLE K STORES SITE: CIRCLE K 2701205 <br /> IIIIIIIIIIIIIIIIII,.,. TANK INFORMATION`.. <br /> Tank ID: 1 Tank manifolded: NO Bottom to top fill in inches: 118.0 <br /> Product: UNLEADED Vent manifolded: YES Bottom to grade in inches: <br /> Capacity in gallons: 11,849 Vapor recovery manifolded: YES Fill pipe length in inches: <br /> Diameter in inches: 118.00 Overfill protection: YES Fill pipe diameter in inches: <br /> Length in inches: 253 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DN FIBERG Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> TANK T€„A,T t2g4,ULT 'St^Method: NONE ga-,, EAK DETECTOR TEST RESUL <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: RED JACKET <br /> Fluid volume in gallons: Model: HK1v <br /> Tank water level in inches: S/N: 2155 <br /> Test time: NOT Open time in sec: 3.00 <br /> Number of thermisters: TESTED Holding psi: 20 NOT <br /> Specific gravity: Resiliency cc: 80 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 10 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> Et <br /> ULTSTest Method:NONE LIN S <br /> Test time: <br /> Ullage volume: Material: DW FIEERG <br /> Ullage pressure: Diameter(in): 2.0 <br /> Results: Length (ft): 80.0 <br /> Test psi: <br /> DATA FOR UTS-4T ONLY: Bleedback cc: <br /> Time of test 1: Test time(min): <br /> Temperature: NOT Start time: NOT NOT NOT NOT <br /> Flow rate(dh): TESTED End time: TESTED TESTED TESTED TESTED <br /> Time of test 2: Final gph: <br /> Temperature: Result: <br /> Flow rate(cin): Pump type: PRESSURE <br /> Time of test 3: Pump make: RED JACKET <br /> Temperature: <br /> Flow rate(cfh): Impact Valves Operational: YES <br /> COMMENTS COMMENTS <br /> Printed 10/28/2010 08:45 ACRAMER <br />