Laserfiche WebLink
t <br /> OUTPUT RELAY SETUP <br /> LIQUID SENSOR SETUP — — — — — — — — — — <br /> R 1 :87 STP <br /> T 2:SUP 92 L 1 :SUP ANN TYPE: <br /> STANDARD <br /> NORMALLY CLOSED <br /> PRODUCT CODE 2 TRI—STATE (SINGLE FLOAT) <br /> THERMAL COEFF : .000700 CATEGORY : ANNULAR SPACE <br /> TANK DIAMETER 96.0G TANK #: 1 <br /> TANK PROFILE 4 PTS <br /> FULL VOL 12024 <br /> 72.0 INCH VOL : 9750 L 2:SUP SUMP LIGU1D SENSOR. ALMS <br /> 48.0 INCH VOL 6097 TRI-STATE (SINGLE FLOAT) L 4:FUEL ALARM <br /> 24.0 INCH VOL 2423 CATEGORY : CTP SUMP L 4:SENSOR OUT ALARM <br /> ALL:SHORT ALARM <br /> FLOAT SIZE: 4.0 IN. L 3:UNL ANN 2 WIRE CL ALARMS <br /> TRI-STATE cSINGLE FLOAT) ALL:FUEL ALARM <br /> WATER WARNING 1 .0 CATEGORY : ANNULAR 2PACE AL.L.:SENSOR OUT ALARM <br /> HIGH WATER LIMIT: 2.0 ALL.:SHORT ALARM <br /> MAX OR LABEL VOL: 12024 ISE) SITE ALARMS <br /> OVERFILL LIMIT 901'; L 4:UNL BLIMP ISD GROSS FRES FAIL <br /> 10821 TRI--STATE (SINGLE FLOAT) ISD DEGRD PRES FAIL <br /> HIGH PRODUCT 95% CATEGORY STP SUMP ISLE VAPOR LEAF. FAIL <br /> 11422 ISD VP PRES FAIL <br /> DELIVERY LIMIT 10% ISD VP STATUS FAIL <br /> 12 0'2 <br /> I SD HOSE ALARMS <br /> LOW PRODUCT : 750 ALL:FLOW COLLECT FAIL <br /> LEAK ALARM LIMIT: 99 <br /> SUDDEN LOSS LIMIT: 99 R 2:92 STP <br /> TANK TILT 0.00 'TYPE: <br /> PROBE OFFSET 0.00 STANDARD <br /> NORMALLY CLOSED <br /> SIPHON MANIFOLDED TANKS TANK 9: <br /> TI1: NONE 2 WIRD: CL SENSOR SETUP y <br /> LINE MANIFOLDED TANKS - - - - - - - - <br /> T#' NONE LIQUID SENSOR ALMS <br /> C 1 :3-4 L 2:FUEL ALARM <br /> DISCRIM. INTERSTITIAL L 2:SENSOR OUT ,ALARM <br /> LEAK MIN PERIODIC: 0°� CATE(UOR`z' : DISPENSER PAN ALL'SHORT ALARM <br /> PERIODIC TEST TYPE 2 WIRE CL ALARMS <br /> QUICK ALL:FUEL ALARM <br /> C 2:7-6 ALL:SENSOR OUT ALARM <br /> PERIODIC TEST FAIL DISCRIM. INTERSTITIAL ALL:SHORT ALARM <br /> ALARM DISABLED CATEGORY : DISPENSER PAhd <br /> ISD SITE ALARMS <br /> GROSS TEST FAIL ISD GROSS PRES FAIL. <br /> ALARM DISABLED ISD DEGRD PRES FAIT, <br /> C 3:11--12 ISD VAPOR LEAK FAIL <br /> PER TEST AVERAGING: OFF DISCRIM. INTERSTITIAL ISD VP PRES FAIL <br /> CATEGORY : DISPENSER PAN ISD VP STATUS FAIL <br /> TANK TEST NOTIFY: OFF <br /> ISD HOSE ALARMS <br /> TNK TST SIPHON BREAK:OFF C 4:1-2 ALL:FLOW COLLECT FAIL <br /> DELIVERY DELAY 5 MIN DISCRIM. INTERSTITIAL R 3:OVERFILL ALARM <br /> PUMP THRESHOLD : 10.00% CATEGORY : DISPENSER PAN TYPE: <br /> STANDARD <br /> NORMALLY OPEN <br /> C 5:9 10 TANK #: NONE <br /> DISCRIM. INTERSTITIAL <br /> CATEGORY : DItiPENSER PAN <br /> IN-TANK ALARML, <br /> ALL:OVERFILL ALARM <br /> ALL:HIGH PRODUCT ALARM <br /> C 6:5-6 ALL:MAX PRODUCT ALARM <br /> DISCRIM. IgrERSTITIAL <br /> CATEGORY DISPENSER PAN ISDHOSE <br /> ALARMSCOLLECT FAIL <br /> LEAK 'TEST METHOD <br /> TEST ON DATE ALL TANKR E C E I a L <br /> JAN 29, 2009 O� V <br /> START TIME : DISABLED <br /> TEST DURATION£ :0220HR <br /> HOURSMAY 11 2017 <br /> TST EARLY STOP:D[SABLES - _.._ .._- ._ ... • <br /> LEAK TEST REPORT FORMAT Ei�iViR^�V�sf� iA�-::E,!3 H <br /> NORMALPERT IITf::.!=r ;:: 3 <br />