My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 9:47:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 2016 - PRESENT.pdf
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/18/2016 5:11:43 PM
QuestysRecordID
3261353
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
oRquly. <br /> SAN JOAQUIN COUNTY <br /> t° ` ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> (209)468-3420 Fax: (209)468-3433 Web:www.sogov.org/�eIM <br /> STORAGE TANK PROGRAM <br /> NOTICE OF SIGNIFICANT VIOLATION <br /> Imminent Threat— Red Tagged No Imminent Threat <br /> E:1Possible Red Tag Within 7' Days <br /> Gtt <br /> Facility Country Marketplace Date: Jan 3, 2018 <br /> Name: <br /> Facility 1789 W Charter Way <br /> Addcity: STOCKTON, CA zip code: 95206 <br /> ress <br /> owneror Harinder Bhade Telephone: (209) 941-2222 <br /> D erator: j <br /> Tank: 87-octane Tank: 91-octane Tank: <br /> Tanks Red Tagged: Product Product Product <br /> Level: Level: Level: <br /> Red Tag Red Tag Red Tag <br /> ID#: ID#: ID#: <br /> Type of significant violation: <br /> 0 A violation that is causing, or threatens to cause a liquid release of petroleum from an underground storage tank <br /> system, including, but not limited to: the failure of any required overfill prevention system, where the failure is <br /> causing or threatens to cause a release; or the failure of a required spill containment structure, where the failure is <br /> causing or threatens to cause a release to the environment due to a spill or an overfill. <br /> ❑ A violation that impairs the ability of an underground storage tank system to detect a liquid leak or contain a liquid <br /> release of petroleum in the manner required by law. <br /> ❑x A chronic violation or a violation that is committed by a recalcitrant violator. In determining whether a violation is <br /> chronic or a violator is recalcitrant, the local agency shall consider whether there is evidence indicating that the <br /> violator has engaged in a pattern of neglect or disregard with respect to any requirement in Title 23 (not including <br /> corrective action). <br /> Per the March 2016 and March 2017 Monitoring System Certification inspection reports, the following violations were <br /> identified and have not been corrected for the Underground Storage Tank (UST) system at the address above: <br /> -Secondary containment testing was last performed on July 14, 2015. According to the test results from July 2015, the 8 <br /> north piping line and the Under Dispenser Containment (UDC) 11112 were not tested. Testing has not been complete <br /> and is 30 months past due. Secondary containment is required once every 36 months (CCR 2637). Immediately schedul <br /> testing for mentioned components and provide 48 hours notification to the Environmental Health Department (EHD). <br /> -The July 14, 2015 secondary containment test results indicate a failure at the 91 annular, UDC 516 and UDC 9110. Al <br /> secondary containment for the UST system must be tight (HSC 25291). Immediately have a properly licensed, trained an <br /> certified contractor repair or replace the failed components under permit and inspection of the EHD. <br /> As a result of the non-compliance, a permit to operate the UST system has not been issued. No person may own o <br /> operate an UST unless a permit for its operation has been issued by the local agency to the owner or operator of the tan <br /> (HSC 25284). The site must be brought into compliance to avoid your entire LIST system being red tagged withi <br /> 7 (seven) days from the receipt of this Notice. <br /> FAILURE TO IMMEDIATELY COMPLY WITH THIS NOTICE MAY RESULT IN ADDITIONAL VIOLATIONS <br /> Inspected By: - v Z_ Print Name: Cesar Ruvalcaba <br /> Signature of R ' tered Environmental Health Specialist <br /> 7 <br /> Received By: Date: v <br /> nerloperator <br /> REV 04/19/12 NOTICE OF SIGNIFICANT VIOLATION <br /> 9171 9690 0935 0152 1701 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.