My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 9:47:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 2016 - PRESENT.pdf
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/18/2016 5:11:43 PM
QuestysRecordID
3261353
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for COUNTRY MARKETPLACE as of October04, 2016. <br /> Open violations from March 08, 2016 inspection <br /> Violation #103 -Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. The financial responsibility documents <br /> submitted for 2015 were actually copies of the 2013 documents with the dates changed and no new, current <br /> signatures. Current financial responsibility documents are required to be submitted annually. Immediately log into <br /> the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required <br /> documents. <br /> Violation #109 - Failed to test secondary containment. <br /> Secondary containment testing was fast performed on July 16, 2012 and was due by July 2015. Testing has not <br /> been completed for all components and is 8 months past due. According to the test results from July 14, 2015, the <br /> 87 north piping line and the UDC 11112 were not tested. Secondary containment testing is required once every 36 <br /> months. Immediately schedule this test and provide 48 hours notification to the EHD. <br /> Violation #201 - Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The 2015 monitoring <br /> certification test results were not found on site. Maintenance records for work done in the last year was not found <br /> on site, including work orders for the secondary containment testing done on July 14, 2015 and the response to an <br /> L1 91 annular alarm on January 16, 2016. These records shall be maintained on site for at least three years. <br /> Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br /> maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br /> field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results, <br /> (6) results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and <br /> monitoring records for the last three years on site and submit copies of the missing records to the EHD. <br /> Violation #314 - Secondary containment not tight. <br /> The July 14, 2015 secondary containment test results indicate a failure at the 91 annular, UDC 5/6, and UDC 9110. <br /> All secondary containment for the UST system must be tight. Immediately have a properly licensed, trained; and <br /> certified contractor repair or replace the failed component under permit and inspection of the EHD. <br /> Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.