Laserfiche WebLink
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PLAZA LIQUOR#1 800 S CHEROKEE LN, LODI March 30, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Facility Operating Permit is not current in CERS. The California Department of Tax and Fee Administration <br /> (formerly Board of Equalization or BOE)number TK STF 44024646 is closed and no longer active. Any change of <br /> information must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the <br /> required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. Monitoring System Certification <br /> reports for 2015, 2016 and 2017 were not found onsite. These records shall be maintained on site for at least three <br /> years. Monitoring records include: (1)date and time of all monitoring or sampling; (2)monitoring equipment <br /> calibration and maintenance records; (3)results of any visual observations; (4)results of sample analysis performed <br /> a lab or in the field; (5)logs of all readings of gauges or other monitoring equipment, ground water elevations,or <br /> other test results; (6)results of inventory readings and reconciliations. Immediately locate and maintain all <br /> maintenance and monitoring records for the last three years on site and submit copies to the EHD. <br /> This is a minor violation. <br /> 306 CCR 2630(d)Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 91 STP sump sensor was raised and found to be between three to four feet above the bottom of the sump and <br /> not located to detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to be able to <br /> detect a leak at the earliest possible opportunity. The sensor was relocated to the lowest point of the sump by the <br /> service technician. Ensure that all monitoring equipment is maintained to detect a leak at the earliest opportunity. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by April 29, 2018 . <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> FA0003997 PR0231325 SCO01 03/30/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />