My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2005 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:48:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2010
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99 E
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\10878\PR0231598\COMPLIANCE INFO 2005 - 2010 .PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2010
QuestysRecordDate
5/17/2017 6:13:49 PM
QuestysRecordID
3384372
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Facility_Marada Chevron 40 Address_10878 N.Hwy 99 Date 0/06 Page?of <br /> 5. SECONDARY PIPE TESTING <br /> Test Method Developed By: ✓piping Manufacturer Industry Standard Professional Engineer <br /> Test Method Used: ✓Pressure Vacuum Hydrostatic <br /> Test Equipment Used: 3.5"gauges Equipment Resolution: .2 psi <br /> Piping Run# 1 Piping Run#2 Piping Run#3 Piping Run#4 <br /> Piping Destination: 87 Unleaded 89 Unleaded Plus Premium Diesel <br /> Piping Material: FRP FRP FRP FRP <br /> Piping Diameter: 3" 3" 3„ 3„ <br /> Length of Piping Run: <br /> Method and location of Test Boots in Sumps Test Boots in Sumps Test Boots in Sumps Test Boots in Sumps <br /> piping-run isolation: and UDC'S and UDC'S and UDC's and UDC's <br /> Wait time between applying <br /> pressure/vacuum/water and 15 min minimum 15 min minimum 15 min minimum 15 min minimum <br /> starting test: <br /> Test Start Time: 2:05 pm 10:25 am 2:17 pm 10:25 am <br /> Initial Reading(RD: 5 psi 5.4 psi 5 psi 5.5 psi <br /> Test End Time: 3:05 pm 11:25 am 3:17 pm 11:25 am <br /> Final Reading(RF): 5 psi 5.4 psi 5 psi 5.5 psi <br /> Test Duration: I hr I hr 1 hr 1 hr <br /> Change in Reading(RF-Rt): 0 0 0 0 <br /> Pass/Fail Threshold or 2 psi .2 psi .2 psi .2 psi <br /> Criteria: <br /> Test Result: 4 Pass ❑Fail 1 J Pass ❑Fail 1 J Pass ❑Fail Pass ❑Fail <br /> Comments (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.