My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2005 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:48:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2010
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99 E
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\10878\PR0231598\COMPLIANCE INFO 2005 - 2010 .PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2010
QuestysRecordDate
5/17/2017 6:13:49 PM
QuestysRecordID
3384372
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPAER CONTAINMENT (POC) TESTING <br /> Test Method By: o Manufacturer • Industry Standard o Professional Engr o Other(see below) <br /> Test Method Uses: O Pressure vacuum • Hydrostatic o Other(see below) <br /> Measuring Equipment Used: INCON TS-STS (Electronic Sump Test System) <br /> Description Disp#1/2 Disp#3/4 Disp#5/6 Disp#7/8 <br /> UDC manufacturer Bravo Bravo Bravo Bravo _ <br /> UDC material Steel Steel Steel Steel <br /> UDC depth (inches) 9 9 _ 9 9 <br /> Height from UDC bottom to highest Bottom Bottom Bottom Bottom <br /> piping penetration <br /> Height from UDC bottom to lowest Bottom Bottom Bottom Bottom <br /> electrical penetration _ <br /> Condition of UDC prior to testing Dry Dry _ Dry _ Dry <br /> Portion of UDC tested Entire Entire Entire Entire <br /> Type of shut-down present Float Float _ Float __ Float <br /> Was sensor removed for testing? N/A N/A N/A _ N/A <br /> Was sensor properly replaced after testing? N/A N/A N/A N/A <br /> Depth of water level from UDC bottom (in.) 6 6 _ 6 6 <br /> Wait time for water level to stabilize (hr:min) 0:05 0:10 0:10 0:05 <br /> Test start time 1:30 PM 1:30 PM 12:22 PM 12:22 PM _ <br /> Initial Probe Reading 0.1924 0.7132 0.4227 0.9769 <br /> Test end time 1:45 PM 1:45 PM 12:37 PM 12:37 PM <br /> Final Probe Reading 0.1924 0.7124 0.4232 0.9763 <br /> Test duration (hr:min) 0:15 0:15 0:15 0:15 <br /> Change in water level (±0.0000 inches) 0.0000 -0.0008 0.0005 -0.0006 <br /> Pass/Fail threshold (±0.0020 inches/;Hr.) 0.0020 0.0020 _ _ 0.0020 0.0020 <br /> TEST RESULT PASS PASS PASS PASS <br /> Comments: <br /> 2004 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.