COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:14 PM
Creation date
11/8/2018 9:48:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99 E
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\10878\PR0231598\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
5/17/2017 4:28:22 PM
QuestysRecordID
3383804
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for MORADA CHEVRON FAST N EASY #60* as of March 11, <br /> 2017. <br /> Open violations from March 11, 2017 inspection <br /> Violation #103 -Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to CERS within the past 365 days. The CFO letter is <br /> greater than 365 days old. Current financial responsibility documents are required to be submitted annually. <br /> Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and <br /> upload the required documents. <br /> Violation #104-UST operating permit application for facility and tank information not submitted or current. <br /> The UST tank information forms for all of the tanks in the California Environmental Reporting System (CERS) <br /> indicates"no"for the striker plate. The tanks all have striker plates under the fill pipes. Correct the tank forms in <br /> CERS and submit the corrections. <br /> Open violations from April 25, 2016 inspection <br /> Violation #201 -Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The April 2015 secondary <br /> containment test results were not found onsite. These records shall be maintained on site for at least three years. <br /> Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br /> maintenance records, (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br /> field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; <br /> (6) results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and <br /> monitoring records for the last three years on site and submit copies to the EHD. <br /> Violation#209 - Designated operator did not inspect all required items and/or the inspection reports not <br /> completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the November 2015 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: An 1-2: 91-2 STP Sump Fuel Alarm on November 16, 2015. During the monthly inspection, <br /> the designated operator shall review the alarm history for the previous month, check that each alarm was <br /> documented and responded to appropriately, and attach a copy of the alarm history with documentation taken in <br /> response to any alarms to the monthly report. Ensure that designated operators performing monthly inspections at <br /> this facility are including all of the required information on the reports. <br /> The designated operator failed to check and note the correct test dates for the Monitoring System Certification, Leak <br /> Detectors and Spill container test on the August 2015 through April 2016 and the May 2015 through June 2015 <br /> designated operator monthly inspection reports. The test date listed on the inspection reports is April 21, 2015. The <br /> correct test date on file is April 22, 2015. During the monthly inspection, the designated operator shall check that all <br /> required testing and maintenance for the UST system have been completed and document the dates they were <br /> done. Ensure that designated operators performing monthly inspections at this facility are including all of the <br /> required information on the reports. <br /> Page 1 of 1 <br />