Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.smqov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> Valley Pacific Petroleum Services, Inc. #1004 March 23, 2011 <br /> Facility address: jProduct <br /> 1 2 <br /> 3550 S. Hwy 99, Stockton ' 87 RED DSLFacility contact: Title: Phone: <br /> Mike Eliason Cardlock Manager 948-9412 <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> ❑X Pressurizetl�uction❑Gravity XMechanical ®M7-RDetect❑M2-RPrev❑M3-Both <br /> Veeder-Root TLS-350 Audible/visual <br /> Inspection type: Designated operator: ICC exp.date: <br /> ❑X Routine ©Monitoring Certification [O]Installation ❑Other Mike Eliason (5250416-UC) 3/22/2013 <br /> On site Service Technician's name: ICC exp.date: Manufacturer's training: <br /> Michael Lawrence (1048103-UT 5/12/2011 VR Lv14 A26642 12/2/2011; VMI #1800 4/22/2012 <br /> VIOLATIONSR <br /> # Code Section HSC=CA Health&SafetyCode; CCR=CA Code of Regulations;V=Violation =Repeat Violation V V <br /> 1 HSC 25284 No permit tooperate <br /> Secondary containment: (a)test not performed;(e)test report not submitted within 30 days; (f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711 b Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file witbitP <br /> 5 CCR 2632(b) Monitorin Program(Monitoring&Response-Plans not curren or approved by the EHD X <br /> 6 CCR 2712(i) Monitoring Ian, response plan and/oroperating erml nditions not onsite <br /> Maintenance&monitoring records not maintained 3 years, cathodic protection records for 6'h (M1) <br /> years,written performance claims pertaining to release detection systems for 5 years, or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations, or other test results;(6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily onitoring of suctionin reJanua 1 1984 not performed M1 <br /> 9 HSC 25292.1 UST s stem is not o erated to revent unauthorized release, including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST Ili X <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(MI) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (Mt) X <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (M1) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in seconds i inq do not flow to a collection sum <br /> 17 CCR 2636 2 Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi (Mt) <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means (Mz) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (Mz <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction in Mz <br /> jins <br /> 25291 a Water in 2'containment not removed, analyzed&properly disposed of X <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight (M1) <br /> 2650 hours was not recorded; (e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 2715 a Failed to inform the EHD of a chain a of desi nated operator within 30 days <br /> 2715 b Desi nated o erator did not possess a current ICC UST System Operator certification <br /> EE <br /> r: r� ) Received by: Title: <br /> gk�w- 4�k4k I <br /> E D 23'02-002 R 08/13/10 �� Page 1 UST INSPECTION REPORT <br />