Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sioov.oro/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> FaciNamlity e: Valley Pacific Hwy 99 Cardlock Address: 3550 S. Hwy 99, Stockton p,�Cd01 Apr 1, 2014 <br /> canl�: Mike Eliason TNe: Cardlock Manager Phone:(209) 993-8793 <br /> Inspection yq Routine X Monitoring System Certification I]Installation O Complaint—iEw. a Otter <br /> Type: <br /> (AuthConsentf HSC 25289) James Abbott Cardlock Technician <br /> Consent for. 7�Inspection 7�Sampling XPhetos Granted by: TNe: <br /> Monitoring el: Veeder-Root TLS-350 P'P"g ) Pessunzetl Suction ❑Gravity Over xMechanical 11AudibleMsual <br /> System: Prevention: <br /> UST 1 2 <br /> Product 87-octane Designated DSL <br /> operator Mike Eliason o t� 4/1/15 violations: 111vi1-Release Detection ❑M2-Release Prevention nM3—Both <br /> On SiteService Richard Thomas ICC Exp. Manufacturers <br /> Date: 12/27/14 Training: VR x. 12/9/14 VMI x. 12/17/14 <br /> VIOLATIONS <br /> # I C1 C2 M Code Section HSC=California Heath and Safety Code'CCR=California Code of Reguirdions <br /> Cl=class 1 violation;C2=Class 2 nidation;M=Minor violation <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating pert was issued to and the tank operator to <br /> monitor the tank system <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Heath Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Fors not on file with the EHD(Facility and tank for) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plar/ste map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed IMI) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(1)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br /> 113 CCR 2715(a) Failed to inform the EHD of a charge of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> cit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 1172CR 2661 Pert to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Peril to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to dose UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment,ground water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(1) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inspecfan Receva0 Dr TNe: <br /> Stacy Rivera (209) 468-3440 <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSOECTION REPORT <br />