My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
3550
>
2300 - Underground Storage Tank Program
>
PR0505827
>
COMPLIANCE INFO_2008-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
11/8/2018 9:49:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2015
RECORD_ID
PR0505827
PE
2361
FACILITY_ID
FA0007030
FACILITY_NAME
VALLEY PACIFIC HWY 99 CARDLOCK
STREET_NUMBER
3550
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17916043
CURRENT_STATUS
01
SITE_LOCATION
3550 S HWY 99
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\3550\PR0505827\COMPLIANCE INFO 2008-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. 1 <br /> t <br /> 2EV7st�b 413 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Name: Valley Pacific Petro. - Hwy. 99 Address: 3550 S. HW 99Stockton Inspection <br /> Y , Date: Apr 2, 2013 <br /> FacContact: Mike Eliason Title: Cardlock Manager g ���) 993-8793 <br /> Inspection <br /> Type: XRoutine $Monitoring System Certification ❑Installation ❑Complaint-ID#: ❑Other; <br /> (Authority HSC 25289) <br /> Consentfor: $Inspection $Sampling XPhotos Granted by.James Abbott Title: Cardlock Technician <br /> Monitoring 9 Veeder-Root TLS-350 System: $Pressurized E Suction []Gravity Overfill <br /> $Mechanical ❑Audible/visual <br /> UST 1 2 <br /> ---Product----- --87-octane-- --Red DSL--- ----------- --------- -- ---- --------- --------------- ---------- --- ------- - <br /> Designated ICC p' <br /> Violations: XM1-Release Detection M2-Release Prevention OM3-Both <br /> Operator: <br /> Designated <br /> James Abbott Date:: 4/17/14 U <br /> Ten Site Service chnician, Richard Thomas ICC : 12/27/14 Training: VR x. 12/9/14 VMI x. 12/17/14 <br /> T aiming: <br /> VIOLATIONS <br /> # I C1 C2 M Code Section HSC=California Health and Safe Code,CCR=California Code of Re ulations <br /> C1 =Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 X CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 1 X I HSC 25291(f) Annual line leak detector lest not performed (Ml) <br /> 111 X HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (Ml) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> ermit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(.) Permit to close UST system not obtained <br /> .; .: On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6 Y years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> e ui ment, round water elevations,or other test results; 6 results of invento readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (Mt) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not Leaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> InsPectoc Received Br Title: <br /> Stacy Rivera (209) 468-3440 d id dell/ <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.