Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:wvvw.siaov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> ARCH ARCO AM PM` (209) 948-2438 February 14, 2017 <br /> Facility Address: <br /> 4855 S HWY 99 FRONTAGE RD, STOCKTON, CA 95215 CERS ID: <br /> 101822: <br /> Inspection Contact: Title: Phone: <br /> 51 <br /> Nima Badial Manager (209) 948-2438 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 - UST FACILITY <br /> Consent For I Consent Given By: <br /> N Inspection ® Photos ® Samples Nima Badial, Manager <br /> Service Technician Onsite Exp.Date: Designated Operator: Exp.Date: <br /> Felix Ramirez 11/22/2018 Felix Ramirez 02/26/2018 <br /> Service Technician Manufacturer's Training <br /> Veeder Root, 07/06/18; VMI, 11/05/17; Tank Tester,05/31/17 <br /> CCH=California(;Ode of egu ations HSC=Health and SafetyCode CFR=Codeo a eral Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate u V ❑R n COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system u V ❑R o COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ❑V in R ❑COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current D V u R ❑COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan ■V ■R ❑COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan ❑V ❑R ❑COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ■V ■R ❑COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing u V u R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment ❑V n R u COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V ❑R ❑COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ■V ■R u COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ■V ■R n COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days .V ❑R in COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V ❑R ❑COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days ❑V o R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification ❑V ❑R ❑COS <br /> f17 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ❑V ❑R ❑COS <br /> 118 CCR 2663 Failed to submit tank lining Certification within 30 days or to conduct proper tests ❑V u R ❑COS <br /> 119 HSC 25299 Documents were falsified or misrepresented ❑V ❑R ❑COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification n V ❑R n COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V ❑R ❑COS <br /> 122 CCR 26310) Failure to submit UST system component statement of compatibility for substance stored n V n R o COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions ■V ■R ❑COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years ❑V u R ❑COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site o V ❑R ❑COS <br /> FA0007571 PRO506650 SCO01 02/14/2017 <br /> EHD 23-01 Rev.09/22/16 Page 1 of 7 Underground Storage Tank Program OIR <br />