My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6.PIPING SUMP TESTING <br /> Test Method Developed By: r Sump Manufacturer r Industry Standard r Professional Engineer <br /> F Other(Specify) <br /> Test Method Used: r Pressure r Vacuum F Hydrostatic <br /> F Other(Specify) <br /> Test Equipment Used: Incon TS-STS Equipment Resolution: .0006 <br /> ump Sump Sump Sump <br /> SurrQ#2 <br /> Sump Diameter: 42" <br /> Sump Depth: 48^ <br /> Sump Material: Fiberglass <br /> I leight from Tank Top to Top of 42„ <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 40" <br /> Electrical Penetration: <br /> Condition of sump prior to Good <br /> testing : <br /> Portion of SumpTested(1) 2" above piping <br /> Does turbine shutdown when r r r r r� r r r r <br /> sump sensor detects liquid(both I Ya I No 1' NA F Yes I No I NA I Ya I No 1 NA F Yu I No I NA <br /> product and water)?* <br /> Turbine shutdown response time N/A r r r /� r r— r r r r r <br /> Is system programmed for fai I- r Yes I Na I- NA 1 Yes 1 ..F NA r Ya I No 1 NA 1 Yes I No 1 NA <br /> safe shutdown?* r r� r r r r— r r r r r— <br /> W as fail-safe verified to be r Yes 1 No r� NA 1 Yea I No I NA I Ya I No I NA 1 Ya 1 No I NA <br /> ,operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 min <br /> starting test: <br /> Test Start Time: 11:49 am 12:11 pm <br /> Initial Reading(Rt): 6.2693 6.2678 <br /> Test End Time: 12:04 pm 12:26 pm <br /> Final Reading(RF): 6.2682 6.2662 <br /> Test Duration: 15 min 15 min <br /> Change in Reading(Rr-RI): .0011 .0014 <br /> Pass/Fail"Threshold or Criteria: .002 1.002 <br /> Test Result: rF Pass r Fail r Pass r Fail r Pass r Fail r Pass r Fail <br /> r� <br /> Was sensor removed for testing? Yea r Nor NA r Yes r No r NA r Yes r No r NA r Yes r No r NA <br /> Was sensor properly replaced and r <br /> verified functional after testing? r Yes I- Nor NA r Yu r No r NA r Ya r No r NA r Yep r No r NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Sensor was reinstalled at lowest point but not tested. <br /> (1) If the entire depth of the sump is not tested,specify how much was tested.Ifthe answer to any of the questions indicated <br /> with an asterisk(*) is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />