My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siclov.org/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Inspection Date: <br /> Facility address: <br /> 3515 Navy Dr., Stockton CA October 8, 2010 <br /> VIOLATIONS y R <br /> # Code Section HSC=CA Health&SafetyCode'CCR=CA Code of Re ulations V=Violation; RV=Re eat Violation V <br /> Designated operator monthly inspection: (c)(1)alarms not documented;(c)(2-4)spill containers, <br /> 23c CCR 2715(c), (e) UDCs, and sumps(if necessary)not inspected;(c)(5)required test dates not checked or noted; (c)(6) <br /> employee trainingnot verified; (e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training:(1)not performed; (2)not current for at least one employee <br /> In_site' 3 to not kept <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 <br /> 24 CCR 2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement,calibration,or certification; (f)performed, and failed to affix a tag/sticker on each <br /> monitoring equipment com onent that was certified, repaired,or replaced <br /> 25 HSC 25291 Annual line leak detector test not erformed M7 <br /> 26 HSC 25284.2 Annuals ill containment testin not pertormea <br /> 27 CCR 2636 4 Annual line ti htnei test notperformed ifositive shutdown or tail safe not resent M1) <br /> 28 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit (M2) <br /> conditions <br /> 29 CCR 2643 a Biennial tightness test of gravity pipingnot performed re-Janus 1, 1984 Mi <br /> 30 CCR 2643 d Triennial line test for conventional sucion piping not p22ormed ipre-januaa 1 1984 M1 <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to re air UST system not obtained <br /> 33 HSC 25286 a O erational ermit not amended when UST storage and/or monitoring system34 25298 b Permit to tem oraril close UST s stem not obtained35 HSC 25298 c Permit to close UST s stem not obtained <br /> 36 HSC 25299 2 Tam erin withor disablin leak detection devices or alarms37 HSC 25298 a Ille all abandoned UST s stem38 HSC 25281.5 b 2 Unburied fuel i in at marinas not visuall ins eked at least dail 39 CCR 2631.1 a UST s stem is not com atiblewith the substance storedEme enc enerator s stemsr monitorin s stem not checked Tail or I nnii)41 HSC 25281.5 b 3 Unburied fuel i in not visuall ins ected at least month) or to n <br /> AB 1702(2003-2004) HSC 25290.2(installed between 07101/03 and 06130104) <br /> VPH Systems HSC 25290.1 installed on or after 07/01/0411 <br /> Compatibility and permeability requirements: (a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 2631 b(and d results forr athe LISTT system llity and installed after Julypermeability12sting requirements listed In subsections CCR <br /> 004,were not submitted <br /> 43 HSC 2229,',,2'((c1)(1,,)5 . Primary containment not liquid or vapor tight <br /> HSC 25c <br /> 44 HSC 252 <br /> HS290.2 c 2 90.1(c)(2) Secondary containment not liquid or vapor tight <br /> C 25 <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or (Mi) <br /> HSC 25290.2 d the entry of liquid or vapor from the rima containment into the secunda containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method, constant vacuum,or constant pressure in the interstitial (M1) <br /> s ace of the UST system not maintained <br /> HSC 25290.1 G) UST system not tested by one of the following methods prior to use: (1)Enhanced leak detection; (2) <br /> 48 HSC 25290.2(1) inert gas pressure test approved by SWRCB; (3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB I L <br /> Other violations <br /> 999 Other: See a hed"Continuation—Official Inspection Reporr'for violation(s)not listed above. <br /> EHO ins r: Phone: <br /> UIC <br /> c10 <br /> c system: <br /> (209) 468-9848 septi <br /> Serves>10 people/day <br /> eceivad by. Title: --Receives other than sanitary waste <br /> V -tel 5 Other disposal <br /> wellsmethodD <br /> C I� v r Q� L;Dry wells/French Drains <br /> EH'D[223-002-002 REV 08/13110 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.