Laserfiche WebLink
. SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK UST PROGRAM INSPECTION REPORT <br /> Facility name: Designated Opel,tpFInspection <br /> I D/_� Date: <br /> V Ge� el4-L , Iv lolo <br /> Facility address: UST# <br /> (f lG Product ,t+4 64W- <br /> Facility Contact: 'Title:' Phone: <br /> AA r Q-S Ttz µ - (o u <br /> Monitoring Panel: Piping system: VOverfill prevention: <br /> ❑Pressurized ❑Suction Gravity ❑Mechanical Audible/visual <br /> n pection type: Violations: <br /> )CRoutine onitorm Certification [I Installation Ll Other: M1-,Detect ❑M2-RPrev ❑M-3 Both <br /> # Code Section <br /> VIOLATION(S) HSC=California Health &Safety Code;CCR=California Code of Regulations V R V=Violation; RV=Re eat Violation V <br /> 1 HSC 25284 Permit to operate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 b & c Current Unified Program Consolidated Forms on file with EHD (Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 b Monitoring Program (Monitoring&Response Plan is current and approved by the local agency. <br /> 6 CCR 2712 i Monitoring Ian is onsite. <br /> 7 CCR 2712 b Maintenance&monitoring records M1 <br /> 8 CCR 2643 d Daily monitoring of suction piping (pre-January, 1, 1984 <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitorings stem is present M1 <br /> 11 CCR 2630 d UST system monitoring equipment is properly located to detect a leak (M1 <br /> 12 HSC 25291 b UST system monitoring equipment is operational (M1) <br /> 13 CCR 2636 1 Continuous monitoring system for underground piping & UDC is present M1 <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636 (c)(1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 Line leak detectors are installed M1 <br /> 18 CCR 2635(b)(1) Spill container M2 <br /> 19 CCR 2635(b)(2) Overfill revention system M2 <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&2°containment <br /> 21 HSC 25291 (e) Water in 20 containment analyzed& properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases (M1) <br /> 23 CCR 2715 Design ted Operator: a Statement from UST owner; (c-e)Monthly inspection; Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638 a Annual line leak detector test M1 <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636 4 Annual line tightness test (M1 <br /> 28 CCR 2661 ffl Repair for tank/piping has had tightness test (M2) <br /> 29 CCR 2643 a Biennial tightness test of gravity piping (pre-January 1, 1984 <br /> 30 CCR 2643 d Triennial line test for conventional suction piping (pre-January 1, 1984) (M7) <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 b Permit to temporarily close UST system <br /> 35 HSC 25298 c Permit to close UST system <br /> 36 HSC 25299 Disabling leak detection devices <br /> a 9 2 <br /> 37 HSC 25298 a Illegal abandonment of UST system <br /> 38 Other: <br /> EHD INSPECTOR: PHONE: UIC <br /> ZJ01 b bye' Se 'cs stem: <br /> ❑ s>_20 people/day <br /> RECEIV D Y: TITLE: ❑Race; ther than sanitary waste <br /> /- Other dis osal ods: <br /> B /� ❑Dry walls/French ins <br /> EHD 23-02-002 R 8/08 UST INSPEC FINAL <br />