My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work.A copy of is orm mus a pmvi e o e an sys em owner opera or.The <br /> owner/operator mus su mi a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility: Shell Shell Stockton Terminal Bld No: DOSHE05 <br /> Address: 3515 Navy Dr. Citv: Stockton Zi : <br /> FacilitV Contact Person: TOM EIKEMEIRER Contact Phone No: 916.997.0054 <br /> Make/Model of Monitoring System: RONAN X76S IService Date: 10/15/2007 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspectecilserviced: <br /> Tank ID: RECLAIM TANK Tank ID: <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ® Annular Space or Vault Sensor Model: LS-7 ❑ Annular Space or Vault Sensor Model: <br /> ® Piping Sump/Trench Sensor(s) Model:LS-3 ❑ Piping Sump/Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High Level Sensor Model: ❑ Tank Overfill/High Level Sensor Model: <br /> ®Other(Specify equipment type and model in Section E on Page 2) ❑Other(Specify equipment type and model in Section E on Page 2) <br /> TanklD: TanklD: <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ❑ Annular Space or Vault Sensor Model: ❑ Annular Space or Vault Sensor Model: <br /> ❑ Piping Sump/Trench Sensor(s) Model: ❑ Piping Sump/Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensors) Model: <br /> ❑ Mechanical Line Leak Detector Model: EI Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: El Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High Level Sensor Model: ❑ Tank Overfill/High Level Sensor Model: <br /> Other(Specify equipment type and model in Section E on Page 2) n Other(Specify equipment type and model in Section E on Page 2) <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valve(s) ❑ Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser lD <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valve(s) ❑ Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensors) Model: ❑ Dispenser Containment Sensors) Model: <br /> ❑ Shear Valve(s) p Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced In accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this Information Is correct and <br /> a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ❑system Alarm history report <br /> Technician Name Print : MICHAEL L. STRAWN II Signature: <br /> Certification No: RONAN-76061001 License No: 588098 <br /> Testing Company Name:TAIT ENVIRONMENTAL Phone No: (714)560-8222 <br /> SERVICES <br /> Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.