My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> OCT 2g 2014 <br /> Shell Oil Products US <br /> E�F?ONME TAL SLT -H <br /> October 29, 2014 <br /> Ms. Michelle Henry <br /> San Joaquin County Environmental Health Department <br /> 1868 East Hazelton Avenue <br /> Stockton, CA 95205 <br /> Re: Equilon Enterprises LLC dba Shell Oil Products US <br /> Response to SJCEHD Underground Storage Tank and Hazardous Waste <br /> Generator Inspection, dated 9/29/14 <br /> 3515 Navy Drive,Stockton, CA 95203 (CERS Id: 10157477) <br /> Dear Ms. Henry: <br /> The following corrective actions were taken as follow-up to the violations listed the in the subject <br /> 9/29/14 issued Inspections Reports: <br /> Underground Storage Tank Program Inspection report(dated 9/29/14) <br /> 104—Corrected. The facility Operating permit application -- Id has been corrected in CERS and <br /> is now listed as FA0003747. <br /> UST Tank Information Forms: The following items were reviewed and updated as required in <br /> CERS - Tank Id, piping sump, vent and vapor recovery piping construction, piping/turbine <br /> containment, vent piping transition sump, and fill components. <br /> 106—Corrected. The Monitoring and response plans were reviewed and the Pipe monitoring and <br /> personnel responsibilities were updated as required CERS. <br /> 204— Corrected. The Current monitoring plan is available for inspection in CERS. This copy can <br /> be accessed from the facility via internet. In addition, a printed copy of the HMBP, including the <br /> monitoring plan, is kept at the facility. <br /> 301 — Corrected. The overfill mechanism (float sensor) was replaced and re-tested on 10/24/14 <br /> by TAIT Environmental. A permit was obtained from SJ County EHD prior to the work. An <br /> inspector(Stacy Rivera)was on site to witness the test. A report of this work will be submitted to <br /> the CUPA within 30 days as required. <br /> 326 — Corrected. As described for item 301 above, the overfill mechanism was replaced and <br /> retested as required. <br /> Overall Inspection Comment: regarding the sensor in the piping sump which was not tested on <br /> 9/29/14, this sensor was tested by TAIT on 10/24/14, and passed. A report will be submitted as <br /> required. <br /> Large Quantity Hazardous Waste Generator Inspection Report(dated 9129/14): <br /> 107- This item in the inspection report stated the Contingency plan incomplete, 'Upon review of <br /> the plans provided at the time of inspection a listed emergency coordinator could not be found'. <br /> Immediately prepare or amend an existing plan to fulfill the requirements of this chapter. Submit <br /> a copy of the updated portion of the contingency plan to the EHD. <br />
The URL can be used to link to this page
Your browser does not support the video tag.