COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> Shell Oil Products US-Stockton Terminal (209)466-6941 October 24, 2014 <br /> Facility Address: EPA ID CERS ID: <br /> 3515 Navy Dr, Stockton, CA 95203 1 10157477 <br /> Facility Contact: Contact Phone: Contact during inspection, if <br /> TOM EIKMEIER (209)466-6941 different from facility contact: 'VII ({ r <br /> Inspection type: Program: <br /> INSPECTION/REINSPECTION 1 hr minimum 2361 - UST FACILITY <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Conected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate ❑V ❑R ❑COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V o R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ❑V ❑R ❑COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current ❑V ❑R ❑COS <br /> 105 HSC 25286(c) Current BOE number not submitted ❑V ❑R ❑COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD ❑V ❑R a COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ❑V ❑R ❑COS <br /> 108 CCR 2637(0,2638(e) Failed to notify the EHD 48 hours prior to conducting testing ❑V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment ❑V ❑R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V ❑R ❑COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually [oV n R ❑COS <br /> 112 HSC25284.2 Failed to test spill containers annually ❑R ❑COS113 CCR2638(d) Failed to submit monitoring system certification test report within 30 days ❑R ❑COS114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑R ❑COS115 CCR2715(a) Failed to inform the EHD of a change of designated operator within 30 days ❑R ❑COS116 CCR2715 Designated operator,service tech or installer did not possess current ICC certification ❑R ❑COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well ❑V ❑R ❑COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test ❑V ❑R ❑COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days ❑V ❑R ❑COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after n V o R ❑COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V ❑R ❑COS <br /> 122 HSC 25299 Documents were falsified or misrepresented ❑V o R ❑COS <br /> 123 CCR 2661 Permit to repair UST system not obtained ❑V ❑R ❑COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V ❑R ❑COS <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report n V ❑R ❑COS <br /> 126 1 HSC 25404(e)(4) Failed to report program data electronically o V ❑R u COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions u V o R u COS <br /> BceL y(initial): Inspector:: one: ate: <br /> STACY RIVERA, Senior REHS (209)468-3440 10/24/2014 <br /> Dann 9 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.