Laserfiche WebLink
San Joaquin County is <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone.(209)468-3420 Fax: (209)468-3433 Web:www.sggov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Shell Oil Products US- Stockton Terminal 3515 Navy Dr, Stockton October 24, 2014 <br /> UST System Observations <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V ❑R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty n V ❑R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons n V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present,was overridden,or failed to meet overfill requirements ❑V ❑R n COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R n COS <br /> 328 CCR 2717.1(9) Tampered with red tag o V ❑R ❑COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V o R ❑COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R o COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R n COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V o R o COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed c V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V o R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V o R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> Overall Inspection Comments: <br /> A reinspection was conducted to complete the annual monitoring system certification. Witnessed functionality <br /> verification testing of the waste water piping sump sensor, including sensor out. Passed. No additional violations <br /> were noted at this time. <br /> Consent to perform the inspection, take photos and collect samples was given by Miguel Torres, terminal <br /> manager. The service technician was Victor Guerrero (ICC expiration date: 6/11/15), who had the following <br /> manufacturer's certifications: Ronan X76 (expiration date: 7/26/15). <br /> All EHD staff time associated with today's reinspection will be billed at the current hourly rate ($130). <br /> ace ve y mit ra : Inspector: one: ate: <br /> STACY RIVERA, Senior REHS (209)468-3440 10/24/2014 <br /> Pan.I of d <br />