Laserfiche WebLink
D. Results of Testing/Servicing <br /> • • RECEIVED <br /> Software Version Installed: NA OCT 2 0 2014 <br /> Complete the following checklist: ENVI,RQ111.N1� 1TAL 1"1FIDILT'{._. <br /> I Fv Yes F- No* 'Is theaudiblealalmoperational? yr)t-'�r,q-; i'r� Py9-r <br /> F Yes F No* Is the visual alarm operational' .... _. .__ .... ..� <br /> Yes F No* Were all sensors r isually inspected, functionally tested,and confirmed operational? <br /> Yes r No* Were all sensors installed at lowestpoint of secondary containment and positioned so that other equipment <br /> will not interfere with their <br /> ro r operation? <br /> r Yes r No* If alarms are relayed to a remote monitormgstgnon.. a all communications egmpment(C.1-1.modem) <br /> r N/A operational? <br /> . . ...... ,:� . ..... . .....::....m <br /> r Yes (— No* For pressurized piping systems, does the turbine automatically shutdown if the piping secondary <br /> F N/A containment monitoring system detects a leak, fails to operate,or is electrically disconnected?If yes:which <br /> sensors initiate positive shut-down?(Check all that apply) <br /> r Sump/french Sensors; r Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to leaks and sensor failure/disconnection? <br /> r Yes; r No. <br /> F Yes r No* For tank systems that utilize the monitoring system as the primary tank overfill warning device Q e. no <br /> F N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the <br /> tank fill point(s) and operating properly?If so,at what percent of tank capacity does the alarm trigger? <br /> F Yes* F No Was any monitoring equipment replaced?Ifyes,idennfy specific sensors, probes, or other equipment <br /> °replaced and list the manufacturernameand model for all replacement parts in Section E,below <br /> F- Yes* F- No Was liquid found inside any secondary containment systems designed as dty systems? (Check all that <br /> I` <br /> � W ater. If yes,describe causes in Section E, below. <br /> rapply) r Product; <br /> i _ <br /> rv— Yes F No* Was monitoring system sct-up reviewed to ensureproper setting ? Attach setup reports,if applicable <br /> F- Yes F7 No* Is all mon itoring equ ip ment opemnonal p er manufacturer's s peci ficat ion s? <br /> *N SecfionE blow,describe how and when thesedeBciencieswere or will be corrected. <br /> E. Comments: <br /> Other sensors from page one: <br /> Transition Sump ULS: Certified. <br /> The LS3 overfill alarm did not function and needs to be replaced Failed. <br /> Could Not Test Piping Sump Sensor(LS3) Due to Confined Space. <br />