My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/8/2018 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PERSHING\4501\PR0231233\COMPLIANCE INFO 2010 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
8/26/2016 8:55:39 PM
QuestysRecordID
3176689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� I <br /> FLOAT SIZE: 4.0 IN. <br /> WATER MINIMUM 0.000 <br /> ALL:LOW LIQUID ALARM WATER WARNING 1 .0 <br /> ALL:TEMPERATURE WARNING HIGH WATER LIMIT: 1 .5 <br /> ALL:RELAY ACTIVE WATER ALARM FILTER: LOW <br /> ALL:INSTALI. ALARM <br /> RS-232 END OF MESSAGE ALL:SENSOR FAULT WARN <br /> DISABLED ALL:VACUUM WARNING MAX OR LABEL. <br /> ALL:NO VACUUM ALARM VOLUME : 10028 <br /> AUTO DIAL ALARM SETUP <br /> - - - - - - - - - - - - ISD SITE ALARMS HIGH PRODUCT <br /> ISD STAGE 1 WARN % MAX : 95.0 <br /> D 5:FQ FMS ISD GROSS PRES WARN (GALLONS) : 9527 <br /> ISD GROSS FRES FAIL <br /> IN-TANK ALARMS ISD DEGRD PRES WARN OVERFILL LIMIT <br /> ALL:LEAK ALARM ISD DEGRD PRES FAIL % MAX : 90.0 <br /> ALL:HIGH WATER ALARM ISD VAPOR LEAK WARN (GALLONS) : 9025 <br /> ALL:OVERFILL. ALARM ISD VAPOR LEAK FAIL <br /> ALL!LOW PRODUCT ALARM ISD VP PRES WARN DELIVERY LIMIT <br /> ALL:SUDDEN LOSS ALARM ISD VP PRES FAIL <br /> ALL:HIGH PRODUCT ALARM ISD VP STATUS WARN % MAX . 10.0 <br /> ALL:INVALID FUEL LEVEL ISD VP STATUS FAIL CGALLUNS) 1003 <br /> ALL:PROBE OUT MISSING RELAY SETUF LOW PRODUCT <br /> ALL:HIGH WATER WARNING MISSING HOSE SETUP <br /> AL.L:DELIVERY NEEDED MISSING TANK SETUP VOLUME800 <br /> ALL:MAX PRODUCT ALARM MISS VAPOR FLOW MTR <br /> ALL:GROSS TEST FAIL MISS VAPOR PRES SEN LEAK ALARM LIMIT: 15 <br /> ALL:PERIODIC TEST FAIL MISSING VP INPUT SUDDEN LOSS LIMIT: 40 <br /> ALL:ANNUAL TEST FAIL ISD SETUP WARN TANK TILT 0.00 <br /> ' ALL:PER TST NEEDED WRN ISD SETUP FAIL PROBE OFFSET 0.00 <br /> ALL:ANN TST NEEDED WRN -ISD SENSOR OUT WARN <br /> ALL:PER TST NEEDED ALM ISD SENSOR OUT FAIL <br /> ALL:ANN TST NEEDED ALM PC-ISD FAILURE SIPHON MANIFOLDED TANKS <br /> ALL:TANK TEST ACTIVE Iii: fJOIJE <br /> AL.L:NO CSLD IDLE TIME ISD HOSE ALARMS LINE MANIFOLDED TANKS <br /> ALL:TANK SIPHON BREAK ALL:GROSS COLLECT WARN i Tp: NONE <br /> ALL:CSLD INCR RATE WARN ALL:GROSS COLLECT FAIL I <br /> ALL:ACCU_CHART CAL WARN I ALL:DEGRD COLLECT WARN <br /> ALL:RECC)N WARNING ALL:DEGRD COLLECT FAIL LEAK MIN PERIODIC: 2550707 <br /> ALL:RECON ALARM <br /> ALL:LOW TEMP WARNING ALL:FLOW COLLECT WARN <br /> ALL:MISSING TICKET WARN ALL:FLOW COLLECT FAIL LEAK 191N ANNUAL 50% <br /> ALL:GROSS FAIL LINE TNK ALL:AIRFLOW MTR SETUP 5014 <br /> I <br /> ALL:DELIVY DENSITY WARN VAPOR FLW MTR ALMS <br /> ALL:CHK VAPOR FLOW MTR PERIODIC TEST TYPE <br /> LIQUID SENSOR ALMS STANDARD <br /> ALL:FUEL ALARM PMC ALARMS <br /> ALL:SENSOR OUT ALARM VF EMISSIONS WARN ANNUAL TEST FAIL i <br /> ALL:SHORT ALARM VP EMISSIONS FAIL ALARM DISABLED <br /> ALL:WATER ALARM VP PRESSURE WARN PERIODIC TEST FAIL <br /> ALL:WATER OUT ALARM VP PRESSURE FAIL <br /> ALL:HIGH LIQUID ALARM VP DUTY CYCLE WARN ALARM DISABLED <br /> ALL.[LOW LIQUID ALARM VP DUTY CYCLE FAIL <br /> ALL:LIQUID WARNING PMC SETUP FAIL ! GROSS TEST FAIL <br /> ALARM DISABLED <br /> RECEIVER ALARMS <br /> SERVICE REPORT WARN ANN TEST AVERAGING: OFF <br /> ALARM CLEAR WARNING PER TEST AVERAGING: OFF <br /> DELIVERY REPORT WkIV TANK TEST NOTIFY: OFF <br /> COMM SIDE DIM ALM TNK TST SIPHON BREAKOFF <br /> ALL:DISABLED DIM ALARM - <br /> ALL:COMMUNICATION ALARIN <br /> ALL:TRANSACTION ALARM DELIVERY DELAY 3 MIN <br /> STICK OFFSET 0.00 <br /> RECONCILIATION ALM FN-TANK SETUP PUMP THRESHOLD 10.00% <br /> ALL:PROD THRESHOLD ALM - - _ - _ - _ - - - _ - <br /> ALL:CLOSE SHIFT WARNING <br /> ALL:CLOSE DAILY WARNING T I :RUL <br /> PRODUCT CODE 1 <br /> SMARTSENSOR ALARMS THERMAL COEFF : .000690 <br /> ALL:SETUF DATA WARNING TANK DIAMETER 96.00 <br /> ALL:COMMUNICATION ALARM TANK PROFILE 1 PT <br /> ALL:SENSOR FAULT ALARM FULL VOL : 10028 <br /> ALL:FUEL WARNING METER DATA : YES <br /> ALL:FUEL ALARM END FACTOR: HEMISPHER <br /> ALL:WATER WARNING CAL UPDATE: NEVER <br /> ALL:WATER ALARM <br /> ALL:HIGH LIQUID WARNING <br /> ALL:HIGH LIQUID ALARM <br /> ALL:LOW LIQUID WARNING <br />