My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/8/2018 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PERSHING\4501\PR0231233\COMPLIANCE INFO 2010 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
8/26/2016 8:55:39 PM
QuestysRecordID
3176689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY r <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility 7-Eleven Faa"� 4501 N Pershing Ave, Stockton Inspection Oct 11, 2013 <br /> Name. Address: g Date: <br /> VIOLATIONS <br /> # C7 C2 M Code Section HSC=CA Health and SafetyCode,CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(cominued) <br /> 702 CCR 2843(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2843(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (Mt) <br /> Ottwr violations <br /> 999 Other See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Routine and Monitoring System Certification UST inspection <br /> 109. The testing company performed a cold start of the monitoring panel today before the scheduled <br /> monitoring system certification but did not notify the San Joaquin County Environmental Health <br /> Department (EHD) 48 hours prior to the cold start. A cold start can be done concurrently with the <br /> monitoring system certification without a retrofit permit from the EHD only if the EHD is notified of the <br /> cold start 48 hours prior to the appointment. The alarm history must be printed out prior to the cold start <br /> and presented to the EHD inspector. The inspector filled out the UST retrofit verification form for the <br /> cold start done today. No retrofit permit application is required for today's work. <br /> 201. The April 22, 2013 tank secondary containment results were not found on site. These records <br /> shall be kept on site for at least 3 years. Immediately locate and maintain the test results on site and <br /> submit copies to the EHD by November 11, 2011 <br /> 303. One of the secondary containment pipes under dispenser 3/4 did not drain into the under <br /> dispenser containment. Monitoring equipment shall be maintained to be able to detect a leak at the <br /> earliest possible opportunity. The testing technician removed the pipe plug, allowing proper drainage. <br /> Violation resolved during the inspection. <br /> Note: Complete and submit a copy of the Return to Compliance Certification form with a statement of <br /> how each violation was corrected, including supporting documentation, by November 11, 2013. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> T FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspedo[ Receive0 Title. <br /> EHD 21 v /19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.