MONIT(' 'RING SYSTEM CERTV CATION <br /> MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS-350 <br /> CERTIFICATION / TEST DATE: Au ust 12, 2013 <br /> Al. FACILITY A2. OWNER <br /> Name 7-Eleven Market#2368/Store#17334 Name 7-Eleven, Inc <br /> Address 4501 North Pershing Street,Stockton,CA 95207 Address P.O. Box 711, Dallas,TX 75221 <br /> Phone# 209-951-6745 Phone# 805-523-2949 <br /> Contact Stephen Boyd contact Stephen Boyd <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 1868 E. Hazelton Avenue,Stockton,CA 95202 Address P.O. Box 1025,W.Sacramento,CA 95691 <br /> Notified August 7, 2013 Lic# 617238 A, B,Haz <br /> Inspector Garrett Backus Contact Dulcinea Coven <br /> Phone# 209368-8257 Phone# 916-373-1166 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br /> 131: TANKS <br /> k#1 (Product): Gasoline -87 Tank#2 (Product): Gasollne-91 <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794190.420 ■ Annular Space or Vault Sensor Model: 0794390-420 <br /> ■ Piping Sump/Trench Sensorls) Model: 0794390-352 ■ Piping Sump/Trench Sensogs) Model: 0794/90409 <br /> ❑ Fill Sump Sensorls) Model: ❑ Fill Sump Sensoria) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model' _ _ 2vil nic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: _ /High-Level Sensor Motlel: <br /> ❑ Other (specify equipment in Section E) Model: specify equipment In Section E) Model: <br /> Tank#3 (Product): Tank 04 (Product): _ <br /> ❑ In-Tank Gauging Probe Model: _ _ ❑ In-Tank Gauging Probe Model: <br /> ❑ Annular Space or Vault Sensor Model: ❑ Annular Space or Vault Sensor Model: <br /> ❑ Piping Sump/Trench Sensorls) Motlel: _____ ❑ Piping Sump/Trench Sensoria) Model: <br /> El Fill Sump Sensoria) Model: ❑ FIII Sump Sensoria) Model: <br /> ❑ Mechanical Line Leak Detector Model: _ ❑ Mechanical Line Leak Detector Model; <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model, <br /> ❑ Other (specify equipment in Section E) Model: L❑ Other (specify equipment In Section E) Model: <br /> Bz: DISPENSERS/UDC's <br /> Dispenser#: 1-2 _ _ Dispenser#: 3-4 <br /> ■ Dispenser Containment SemModel: 0784380462 ■ Dispenser Containment Sensor(s) Model: 0784390462 <br /> ■ Shear Valves <br /> '' ■ Shear Valves <br /> [I Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser# Dispenser# <br /> ❑ Dispenser Containment Sensorls) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valvas <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float's)and Chaln(s) <br /> Dispenser#: LDispenser# <br /> ❑ Dispenser Containment Sensorls) Model: ❑ Dispenser Containment Sensorls) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float's)and Chaln(s) ❑ Dispenser Containment Float(s)and Chalnhi <br /> C. CERTIFICATION I certify that the equipment identified In this document Was inspected/serviced In accordance with the manufacturers guidelines. <br /> Attached to this Certification is Information(e.g.manufacturers'checklists)necessary to verify that this information Is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-up ■ Alarm History Report <br /> te.� - Ir-)ak-b', WALTON <br /> Signature: 1 ENGINEERING,INC. <br /> Technician/Cert#: Jessie Wadkins/B35391 5307886-UT Date: August 12, 2013 <br /> 0 2013 Walton Engineering,Inc, <br />