My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/8/2018 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PERSHING\4501\PR0231233\COMPLIANCE INFO 2010 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
8/26/2016 8:55:39 PM
QuestysRecordID
3176689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_ SY1awfEM SET-UP REPORT—(Paget) <br /> RECEIVER ALARMS VAPOR FLW MTR ALMS ANN TEST AVERAGING: OFF <br /> SERVICE REPORT WARN ALL:CHK VAPOR FLOW MTR <br /> ALARM CLEAR WARNING PER TEST AVERAGING: OFF <br /> DELIVERY REPORT WRN pMC ALARMS TANK TEST NOTIFY: OFF <br /> VP EMISSIONS WARN <br /> COMM SIDE DIM ALM VP EMISSIONS FAIL TNK TST SIPHON BREAKOFF <br /> ALL:DISABLED DIM ALARM VP PRESSURE WARN <br /> ALL:COMMUNICATION ALARM VP PRESSURE FAIL <br /> ALLL:TRANSACTION ALARM VP DUTY CYCLE WARN DELIVERY DELAY : 3 MIN <br /> VP DUTY CYCLE FAIL STICK OFFSET 0.00 <br /> RECONCILIATION ALM PMC SETUP FAIL PUMP THRESHOLD : 10.00% <br /> ALL:PROD THRESHOLD ALM <br /> ALL:CLOSE SHIFT WARNING T 2:PUL <br /> ALL:CLOSE DAILY WARNING IN_TANK SETUP_ PRODUCT CODE 2 <br /> SMHkTSENSDR ALARMS THERMAL COEFF : .000700 <br /> ALL:SETUP DATA WARNING T I:RUL TANK DIAMETER 96.00 <br /> TANK PROFILE 1 PT <br /> ALL:COMMUNICATION ALARM PRODUCT CODE I <br /> FULL VOL : 10028 <br /> ALL:SENSOR FAULT ALARM THERMAL COEFF : .000700 METER DATA YES <br /> ALL:FUEL WARNING TANK DIAMETER 96.00 END FACTOR: NONE <br /> ALL:FUEL ALARM TANK PROFILE I PT CAL UPDATE: NEVER <br /> ALL:WATER WARNING FULL VOL 10028 <br /> ALL:WATER ALARM METER DATA YES <br /> ALL:HIGH LIQUID WARNING END FACTOR: NONE FLOAT SIZE: 4.0 IN. <br /> ALL:HIGH LIQUID ALARM CAL UPDATE: NEVER <br /> ALL:LOW LIQUID WARNING WATER WARNING 1 .0 <br /> HLL:LOW LIQUID ALARM FLOAT SIZE: 4.0 IN. HIGH WATER LIMIT: 1 .5 <br /> ALL:TEMPERATURE WARNING MAX OR LABEL VOL: 10028 <br /> ALL:RELAY ACTIVE WATER WARNING 1 .0 OVERFILL LIMIT 90% <br /> ALL:INSTALL ALARM HIGH WATER LIMIT: 1 .5 9025 <br /> ALL:SENSOR FAULT WARN HIGH PRODUCT 95% <br /> ALL:VA000M WARNING MAX OR LABEL VOL: 10028 9526 <br /> ALL:NO VACUUM ALARM OVERFILL LIMIT 90> DELIVERY LIMIT 10% <br /> 9025 1002 <br /> ISD SITE ALARMS HIGH PRODUCT 95% <br /> ISD STAGE I WARN 9526 LOW PRODUCT 900 <br /> ISD GROSS PRES WARN DELIVERY LIMIT 10% LEAK ALARM LIMIT: 15 <br /> ISD GROSS FRES FAIL 1002 SUDDEN LOSS LIMIT: 40 <br /> ISD DEGRD PRES WARN TANK TILT 0.00 <br /> ISD DEGRD FRES FAIL LOW PRODUCT 800 PROBE OFFSET 0.00 <br /> ISD VAPOR LEAK WARN LEAK ALARM LIMIT: 15 <br /> ISD VAPOR LEAK FAIL SUDDEN LOSS LIMIT: 40 <br /> ISD VP PRES WARN TANK TILT 0.00 SIPHON MANIFOLDED TANKS <br /> ISD VP PRES FAIL PROBE OFFSET 0.00 TO: NONE <br /> ISD VP STATUS WARN LINE MANIFOLDED TANKS <br /> ISD VP STATUS FAIL TO: NONE <br /> MISSING RELAY SETUP SIPHON MANIFOLDED TANKS <br /> MISSING HOSE SETUP TO: NONE <br /> MISSING TANK SETUP LINE MANIFOLDED TANKS LEAK MIN PERIODIC: 25% <br /> MISS VAPOR FLOW MTR TO: NONE <br /> MISS VAPOR PRES SEN 2507 <br /> MISSING VP INPUT LEAK MIN ANNUAL 50% <br /> ISD SETUP WARN LEAK MIN PERIODIC: 25% 5014 <br /> ISD SETUP FAIL 2507 <br /> ISD SENSOR OUT WARN <br /> ISD SENSOR OUT FAIL LEAK MIN ANNUAL 50% PERIODIC TEST TYPE <br /> PC-ISD FAILURE 5014 STANDARD <br /> ISD HOSE ALARMS ANNUAL TEST FAIL <br /> ALL:GROSS COLLECT WARN PERIODIC TEST TYPE ALARM DISABLED <br /> ALL:GROSS COLLECT FAIL STANDARD <br /> ALL:DEGRD COLLECT WARN PERIODIC TEST FAIL <br /> ALL:DEGRD COLLECT FAIL ANNUAL TEST FAIL ALARM DISABLED <br /> ALARM DISABLED <br /> ALL:FLOW COLLECT WARN GROSS TEST FAIL <br /> ALL:FLOW COLLECT FAIL PERIODIC TEST FAIL ALARM DISABLED <br /> ALL:AIRFLOW MTR SETUP ALARM DISABLED <br /> GROSS TEST FAIL ANN TEST AVERAGING: OFF <br /> ALARM DISABLED PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF <br /> TNK TST SIPHON BREAK:OFF <br /> DELIVERY DELAY 3 MIN <br /> STICK OFFSET 0.00 <br /> PUMP THRESHOLD 10.00% <br /> 02013 Walton Engineedng.Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.