My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/8/2018 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PERSHING\4501\PR0231233\COMPLIANCE INFO 2010 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
8/26/2016 8:55:39 PM
QuestysRecordID
3176689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page I of 1 <br /> %,, 4.TANK ANNULAR TESTING N,/ <br /> Test Method Developed By: r Tank Manufacturer r Industry Standard r Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure G' vacuum r Hydrostatic <br /> C Other(Specify) <br /> lest Ily uipmrnt I "dEquipment Resolution. 20 si <br /> Tank# l RUL Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' r Yes r No r Yes r No r Yes r No r Yes r No <br /> Tank Capacity: 10028 <br /> Tank Material: Steel <br /> Tank Manufacturer: total containment <br /> Product Stored: RUL <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min min min min <br /> test: <br /> Test Start Time: 10:00:00 <br /> Initial Reading(R1): 15.00000 in.FIG <br /> Test End Time: 08:40:00 <br /> Final Reading(RF): 12.00000 in.FIG <br /> Test Duration: 22.2 hr <br /> Change in Reading(RF-RI): -3.00000 in. HG <br /> Pass/Fail Threshold or Criteria: r/- 5.00000 +/- +/- +/- <br /> Test Result: Pass <br /> Was sensor removed for testing? r Yes r Nor NA r Yes r No r NA r Yes r No r NA r Yes r No r NA <br /> Was sensor properly replaced and r Yes r Nor NA r Yes r Nor NA r Yes r Nor NA r Year Nor NA <br /> verified functional after testing? <br /> Cum ments? include information on re airs made prior to testing,and recommended ollow-u or ailed iests <br /> reg annular was tested 10:00 on 4-22-13 to 8:40 on 4-23-13 and passed. <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment,such as <br /> systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment testing. <br />
The URL can be used to link to this page
Your browser does not support the video tag.