My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/8/2018 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PERSHING\4501\PR0231233\COMPLIANCE INFO 2010 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
8/26/2016 8:55:39 PM
QuestysRecordID
3176689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 1 <br /> TANK ANNULAR TESTING <br /> Test Method Developed By: P Tank Manufacturer 1 Industry Standard r Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure FV Vacuum r Hydrostatic <br /> r Other(Specify) <br /> Test Equipment Used:gauge Equipment Resolution: .20" <br /> Tank# T-1 Tank# T-2 Tank# <br /> Is Tank Exempt From Testing?' ('Yes IT No r Yes(:No r Yes r No <br /> Tank Capacity'. 10028 10028 <br /> Tank Material: Steel Steel <br /> Tank Manufacturer: total containment total containment <br /> Product Stored: RUL PUL <br /> Wail time between applying 5 min 5 min min <br /> pressure/vacuum/water and starting test: <br /> Test Start Time: 09:10:00 091000 <br /> Initial Reading(RI): 15.00000 in. HG 15.00000 in. HG <br /> Test End Time: 08'.20'.00 08:20:00 <br /> Final Reading(RF): 9.00000 in. HG 14.00000 in. HG <br /> Test Duration: 23.1 hr 23.1 hr <br /> Change in Reading(RF-Ri): -8.00000 in. HG -1.00000 in. HG <br /> Pass/Fail Threshold or Criteria: +/-5,00000 +/-5 00000 +/- <br /> Test Result: Fail Pass <br /> Was sensor removed for testing? 0 Yes r Nor NA G. Yes r No r NA r Yes r No NA <br /> Was sensor properly replaced and verified IT Yes r No r NA IT Yes r Nor NA r Yes r Nor NA <br /> functional after testing? <br /> Comments?(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> both annular tests were started on 4-9-13 at 9:10 and ended 4-10-13 at 8:20. <br />
The URL can be used to link to this page
Your browser does not support the video tag.