My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/8/2018 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PERSHING\4501\PR0231233\COMPLIANCE INFO 2010 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
8/26/2016 8:55:39 PM
QuestysRecordID
3176689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Svi January 2002 �.r Page 1 of 1 <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: r UDC Manufacturer r Industry Standard r Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure r Vacuum r Hydrostatic <br /> r Other(Specify) <br /> Test Equipment Used:[W131 Equipment Resolution: . 0001 in <br /> UDC#1/2 '' U4b#3/A ,I UDC# UDC# <br /> uoC Maoufarourer: environ environ j <br /> UDC Material: <br /> UDC Depth: 28.00 28.00 <br /> Height from UDC Bonom to Top of g,00 9.00 <br /> Highest Piping Penetration: <br /> Height from UDC Bottom to Lowest 1.00 1.00 <br /> alecttlul penetatlon: <br /> Condition or UIDC prior to testing: good good <br /> Portion of UDC Tested, 11 11 <br /> Does turbine shut Lown when uoC <br /> sensor detects nquld(both product and r Yes r No NA r Yes r No r NA r Yes r Nor NA r Yes r No r NA <br /> watil <br /> Turbine shutdown response time 02:00:00 set 02:00:005ec sec sec <br /> Is system Programmed for fail-safe r Yes r No rC No IT Yes r No r NA r Yes r No r NA r Yes r No r NA <br /> shumgwnr <br /> Was all-sae warmed m be ope2nomil?- r Yes r No r NA r Yes r No r NA If Yes r No r NA r Yes r Nor NA <br /> Walt time between applying <br /> pressure/vacuum/water and starting tea 5 min 5 min min min <br /> Test start Time: 11:27:00 11:27:00 <br /> Inalel pundits(l 0.00000 In. 0.00000 in. <br /> Test End Tlme: 11:42:00 11:42:00 <br /> Final Reading(RP)! -0.00060 in. -0.00080 in. <br /> Test Duration: <br /> cramps m Reading(Rr-Rp: -0.00060 in. -0.00080 In. <br /> Paaarail Threshold or Chteda: +/- 0.00200 +/-0.00200 +/- +/- <br /> Test ReSYIt: Pass" Pase. <br /> Was senor removed forteaing? r Yes r Nor NA r Yes r No r NA r Yes r Nor NA r Yes r No r NA <br /> saeedfu rprornala replaced and r Yes Nor NA r Yes Nor NA r yes Nor NA r Yesr Nor NA <br /> fled al properly <br /> after lacedpapers? <br /> Comments If(include Information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested, If the answer to any of the questions indicated with an asterisk(*)Is?NO?or?NA?,the <br /> entire UDC must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.