My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/8/2018 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PERSHING\4501\PR0231233\COMPLIANCE INFO 2010 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
8/26/2016 8:55:39 PM
QuestysRecordID
3176689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OCT 2 6 2015 <br /> D.Results of Testing/Servicing - <br /> SoftwareVersionInstalled: 333.03 f=1s V16UN144— TAT. <br /> JflFo•9r7T1AG'^IT <br /> Complete the following checklist: <br /> • yes No* s the audible alarm operational? <br /> • Yes No* s the visual alarm operational? <br /> • yes No* ere all sensors visually inspected,functionally tested,and confirmed operational? <br /> • Yes No* ere all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere wi <br /> heir ro er o ration? <br /> • Yes No* f alarms are relayed m a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> r N/A <br /> • Yes No* For em clef cts piping systems,eras the turbine au lly disconnected? <br /> isn shut down if the piping secondary containment monitoring <br /> em detects a leak,fails to operate,or is electrically Olsconnected7lf yes:which sensors initiate positive shut-down?(Check <br /> r N/A II that apply'sump/Trench Sensors; n Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection'A Yes; C No <br /> Yes l No' For tank systems that utilize the monitoring system as the primary tank Overfill warning device(i.e.no mechanical overfill <br /> C„ N/A prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly?If <br /> at what rcent of tank ca acity,does the alarm trigger?% <br /> Y,,,. No as any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> anufacturer name and model for all replacement parts in Section E below. <br /> Yes* No as liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) <br /> Product r Water.If es describe causes in Section E below. <br /> • Yes No* as monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> • Yes No* s all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E.Comments: <br /> Monitoring System Certification Page 2 of 3 12/07 <br />