Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:18 AM
Creation date
11/8/2018 9:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PERSHING\4501\PR0231233\COMPLIANCE INFO 2010 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2010 - 2015
QuestysRecordDate
8/26/2016 8:55:39 PM
QuestysRecordID
3176689
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
309
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 1 of 1 <br /> 7.UNDER-DISPENSER CONTAINMENT C TESTING <br /> est Method Developed By: UDC Manufacturer W Industry Standard r Professional Engineer <br /> r Other(specify) <br /> Test Method Used By: r Pressure r vacuum r Hydrostatic <br /> r Other(Specify) <br /> Test Equipment Used: VPLT F, ui ment Resolution:0.00001 in. <br /> UDC#1/2 UDC#3/4 UDC# UDC# <br /> UDC Manufacturer: environ environ <br /> UDC Material: _ <br /> UDC Depth: 28.00 28.00 <br /> Height from UDC Bottom to Top 900 9.00 <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 100 100 SEP 2 2015 <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to good good EN IRONMENTA <br /> testin : <br /> Portion of UDC Tested' 11 11 <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both a Yes r Nor NA is Yes r No(NA r Yes r Nor NA r Yes r Nor NA <br /> product and water)?* <br /> Turbine shutdown response time 02:00:00 sec 02:00:00 sec sec sec <br /> Is system programmed for fail- r,: Yes r Nor NA r► Yes r Nor NA r Yes r NorNA r Yes r Nor NA <br /> safe shutdown?* <br /> Was fail-safe verified to be re Yes r Nor NA 9 Yes r NorNA r Yes r Nor NA r Yes f Nor NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 5 min 5 min min min <br /> starting test <br /> Test Start Time: 09:35:00 10:15:00 <br /> Initial Reading(R)): 0.00000 in. 0.00000 in. <br /> Test End Time: 09:50:00 10:30:00 <br /> Final Reading(RF): 0.00050 in. -0.00010 in. <br /> Test Duration: 15 min 15 min <br /> Change in Reading(RF-RI): 0.00050 in. -0.00010 in. <br /> Pass/Fail Threshold or Criteria: +/-0.00200 +/-0.00200 +/- +/- <br /> Test Result: Pass Pass <br /> Was sensor removed for testing? IT Yes r Nor NA r Yes r Nor NA r Yes r Nor NA r Yes r Nor NA <br /> Was sensor properly replaced and G yes r Nor NA r Yes r Nor NA r Yes r Nor NA r Yes r Nor NA <br /> verified functional after testing? <br /> COmmeStS—(include information on repairs made prior to testing, and recommended follow-up for jailed tests) <br /> If the entire depth of the UDC is not tested,specify how much was tested.If the answer to any of the questions indicated with m asterisk(•)is"NO"or"NA",the entire UDC must <br /> be tested. <br /> WO:2324076 <br />
The URL can be used to link to this page
Your browser does not support the video tag.