Laserfiche WebLink
Appendix VI QQ QV E D <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at h / IL4.0 <br /> MONITORING SYSTEM CERTIFICATION OCT 17 2016 <br /> For Use By All Jurisdictions Within the State of California q���tp <br /> Aut ho <br /> Regulations El... <br /> Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California C <br /> I AL HEALTH <br /> ,,AA TMENT <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be p p r each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this forth to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7-ELEVEN#17334 MKT 2368(N-747) Bldg. No.: <br /> Site Address: 4501 N.PERSHING AVE.@ ROSEMARIE LN. City: STOCKTON Zip: 95207 <br /> Facility Contact Person: MGR-SATBIR Contact Phone No.: 209-9516745 <br /> Make/Model of Monitoring System: Veeder Root TLS-350R Date of Testing/Servicing: 10/5/2016 <br /> B.Inventory of Equipment Tested/Cerdfied <br /> Check the appropriate boxes to indicatespecific equipment ins ected serviced: <br /> Tank ID: T-1-RUL Tank ID: T-2-PUL <br /> I7o In-Tank Gauging Probe. Model: 846390-107 r In-Tank Gauging Probe. Model: 846390-107 <br /> V Annular Space or Vault Sensor. Model: 794390420 IV Annular Space or Vault Sensor. Model: 794390420 <br /> 174 Piping Sump/Trench Sensor(s). Model: 794380-352 Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> r Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> r Mechanical Line Leak Detector. Model: Red Jacket FXSV Mechanical Line Leak Detector. Model: Vaporless LD-2000 <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment and model in Section E on Page 2). Other(specify equipment type and model in Section E on Pae 2). <br /> Tank ID: Tank ID: <br /> r In-Tank Gauging Probe. Model: r In-Tank Gauging Probe. Model: <br /> r Annular Space or Vault Sensor. Model: r Annular Space or Vault Sensor. Model: <br /> r Piping Sump/Trench Sensor(s). Model: r Piping Sump/Trench Sensor(s). Model: <br /> r Fill Sump Sensor(s). Model: r Fill Sump Senscr(s). Model: <br /> r Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment type and model in Section E on Pae 2 . Other(specify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 794380-352 rI Dispenser Containment Sensor(s).Model: 794380-352 <br /> Pr Shear Valve(s). WO Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chaln(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this forth.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report, (check all that apply):Pr System set- <br /> up Pr Alarm history report <br /> Technician Name(print): Steve Willems Signature: �XXI <br /> Certification No.: 836743 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)8004633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 10/5/2016 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />