Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sioov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 7-ELEVEN INC#17334 4501 N PERSHING AVE, Stockton October 03, 2017 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status c V o R c COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R It COS <br /> 324 CCR 2717.1(8) Tampered with red tag o V o R o COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V it R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V o R o COS <br /> 328 HSC 25298 Failed to mply with temporary closure requirements o V o R o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements o V o R o COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V o R o COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V o R o COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V o R o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R In COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation QV o R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation o V o R o COS <br /> 2060 See below Unlisted Design/Construction violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS ll,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for both tanks is not current in CERS. In the"Tank Construction"section under <br /> "Overfill Protection", change"Yes"to"No"for 'Audible/Visual Alarms". This facility does have an audible and visual <br /> alarm that would alert the transfer operator of an overfill. Any change of information must be updated in CERS <br /> within 30 days of the changes. Immediately log into CERS, update the required information, and submit for review <br /> by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For tank ID#1 in the"Pipe Monitoring is <br /> Performed Using the Following Method(s)"section change"Leak Sensor Model"794380-352 to 793380-208. For <br /> both tanks in the"Under Dispenser Containment(UDC)Monitoring"section change"Yes"to"No"for"UDC <br /> Monitoring Stops Flow of Product at Dispenser"The monitoring plan must be uploaded to the California <br /> Environmental Reporting System(CERS). Immediately log into CERS, make the necessary changes,and submit <br /> for review by the EHD. <br /> This is a minor violation. <br /> FA0002479 PRO231233 SCO01 IOIOMO17 <br /> EHD 23-01 Rev.09/22116 Page 3 of 6 Underground Storage Tank Program OIR <br />